文献速递神经MR

生成对抗网络在脑TOF-MRA超分辨率中的应用:图像质量与诊断效能评估

Super-resolution application of generative adversarial network on brain time-of-flight MR angiography: image quality and diagnostic utility evaluation.
PubMed 文献 · Eur Radiol · 2022-08-25

本研究纳入180例接受1分钟低分辨率与4分钟高分辨率脑TOF-MRA扫描的患者,用50例训练、12例定量评估、其余做诊断验证,改进pix2pix GAN。结果显示GAN重建图像质量指标与血管可见度均优于低分辨率图像,在动脉瘤、狭窄、闭塞检测上敏感度与特异度相当,一位评估者动脉瘤检测敏感度更高(93% vs 84%)。

要点

  • GAN可将1分钟低分辨率脑TOF-MRA重建为接近常规高分辨率的图像质量。
  • GAN-MRA血管可见度评分显著高于低分辨率图像,两位评估者均一致。
  • GAN-MRA检测动脉瘤、狭窄、闭塞的敏感度与特异度与低分辨率图像相当。

关键影像表现/征象

  • GAN-MRA的MS-SSIM为0.87,高于低分辨率MRA的0.73(p.adjusted < 0.001)。
  • GAN-MRA的ISSM指数为0.60,高于低分辨率MRA的0.35(p.adjusted < 0.001)。
  • 评估者A血管可见度评分为4.18,高于低分辨率MRA的2.53(p.adjusted < 0.001)。
  • 评估者B血管可见度评分为4.61,高于低分辨率MRA的2.65(p.adjusted < 0.001)。

诊断标准与关键数值

  • 血管可见度采用5点Likert量表由两位放射科医生评分。
  • 图像质量定量比较采用MS-SSIM与ISSM指数。
  • 诊断效能以敏感度与特异度评估,针对动脉瘤、狭窄、闭塞。
  • 一位评估者GAN-MRA检测动脉瘤敏感度为93%,低分辨率MRA为84%(p < 0.05)。

临床应用与阅片要点

  • GAN重建可在缩短扫描时间的同时提供接近常规高分辨率的TOF-MRA图像,有望用于临床。
  • GAN-MRA未产生大量假阳性或假阴性,诊断性能未降低。
  • 阅片时仍需注意GAN重建可能引入的伪影或失真,尤其在细小血管评估中。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a generative adversarial network (GAN) model to improve image resolution of brain time-of-flight MR angiography (TOF-MRA) and to evaluate the image quality and diagnostic utility of the reconstructed images.

METHODS: We included 180 patients who underwent 1-min low-resolution (LR) and 4-min high-resolution (routine) brain TOF-MRA scans. We used 50 patients' datasets for training, 12 for quantitative image quality evaluation, and the rest for diagnostic validation. We modified a pix2pix GAN to suit TOF-MRA datasets and fine-tuned GAN-related parameters, including loss functions. Maximum intensity projection images were generated and compared using multi-scale structural similarity (MS-SSIM) and information theoretic-based statistic similarity measure (ISSM) index. Two radiologists scored vessels' visibilities using a 5-point Likert scale. Finally, we evaluated sensitivities and specificities of GAN-MRA in depicting aneurysms, stenoses, and occlusions.

RESULTS: The optimal model was achieved with a lambda of 1e5 and L1 + MS-SSIM loss. Image quality metrics for GAN-MRA were higher than those for LR-MRA (MS-SSIM, 0.87 vs. 0.73; ISSM, 0.60 vs. 0.35; p.adjusted < 0.001). Vessels' visibility of GAN-MRA was superior to LR-MRA (rater A, 4.18 vs. 2.53; rater B, 4.61 vs. 2.65; p.adjusted < 0.001). In depicting vascular abnormalities, GAN-MRA showed comparable sensitivities and specificities, with greater sensitivity for aneurysm detection by one rater (93% vs. 84%, p < 0.05).

CONCLUSIONS: An optimized GAN could significantly improve the image quality and vessel visibility of low-resolution brain TOF-MRA with equivalent sensitivity and specificity in detecting aneurysms, stenoses, and occlusions.

KEY POINTS: • GAN could significantly improve the image quality and vessel visualization of low-resolution brain MR angiography (MRA). • With optimally adjusted training parameters, the GAN model did not degrade diagnostic performance by generating substantial false positives or false negatives. • GAN could be a promising approach for obtaining higher resolution TOF-MRA from images scanned in a fraction of time.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wicaksono, Fujimoto, Fushimi, et al. Super-resolution application of generative adversarial network on brain time-of-flight MR angiography: image quality and diagnostic utility evaluation. Eur Radiol. 2022. PMID: 36006430. doi:10.1007/s00330-022-09103-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。