剪切波弹性成像作为乳腺超声检查中无异常腋窝淋巴结评估的补充工具
该前瞻性研究对175名女性的177个临床及超声无异常腋窝淋巴结行剪切波弹性成像(VTIQ),测得淋巴结皮质、门部及周围脂肪组织的平均硬度分别为1.90 m/s、2.02 m/s和1.75 m/s,皮质和门部硬度显著高于脂肪组织(p<0.0001)。SWE评估淋巴结门部、皮质及周围脂肪组织的重测信度良好(ICC分别为0.79、0.75、0.78)。研究确定了无异常腋窝淋巴结的SWE参考值,有助于联合其他淋巴结特征识别乳腺癌腋窝淋巴结转移。
要点
- 无异常腋窝淋巴结皮质、门部、周围脂肪的平均硬度分别为1.90、2.02、1.75 m/s。
- 皮质和门部硬度显著高于周围脂肪组织(p<0.0001)。
- SWE评估淋巴结门部、皮质及脂肪的ICC分别为0.79、0.75、0.78,重测信度良好。
关键影像表现/征象
- 无异常腋窝淋巴结皮质平均硬度为1.90 m/s(SD: 0.34 m/s)。
- 无异常腋窝淋巴结门部平均硬度为2.02 m/s(SD: 0.37 m/s)。
- 无异常腋窝淋巴结周围脂肪组织平均硬度为1.75 m/s(SD: 0.38 m/s)。
诊断标准与关键数值
- 皮质和门部硬度显著高于脂肪组织(p < 0.0001)。
- 淋巴结门部、皮质和周围脂肪组织的组内相关系数分别为0.79(95% CI: 0.75; 0.83)、0.75(95% CI: 0.70; 0.79)、0.78(95% CI: 0.74; 0.82),p < 0.0001。
临床应用与阅片要点
- 可将SWE测得的无异常腋窝淋巴结硬度参考值(皮质1.90 m/s、门部2.02 m/s、脂肪1.75 m/s)用于日常阅片对照。
- SWE可作为乳腺超声检查中评估腋窝淋巴结的补充工具,联合其他淋巴结特征辅助识别转移。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To define reference values for shear wave elastography (SWE) in unsuspicious axillary lymph nodes in patients undergoing breast ultrasound examination.
METHODS: In total, 177 clinically and sonographically unsuspicious axillary lymph nodes were prospectively evaluated with SWE using Virtual Touch Tissue Imaging Quantification (VTIQ) in 175 women. Mean values of tissue stiffness for axillary fatty tissue, lymph node cortex, and lymph node hilus were measured. Additionally, test-retest reliability of SWE in the assessment of axillary lymph node stiffness was evaluated by repeating each measurement three times.
RESULTS: In 177 axillary lymph nodes, the mean stiffness of lymph node cortex, hilus, and surrounding fatty tissue as quantified by SWE was 1.90 m/s (SD: 0.34 m/s), 2.02 m/s (SD: 0.37 m/s), and 1.75 m/s (SD: 0.38 m/s), respectively. The mean stiffness of cortex and hilus was significantly higher compared to fatty tissue (p < 0.0001). SWE demonstrated good test-retest reliability in the assessment of stiffness of the lymph node hilus, cortex, and the surrounding fatty tissue with an intraclass correlation of 0.79 (95% CI: 0.75; 0.83), 0.75 (95% CI: 0.70; 0.79), and 0.78 (95% CI: 0.74; 0.82), respectively, (p < 0.0001).
CONCLUSIONS: Reference values for SWE in unsuspicious axillary lymph nodes are determined. These results may help to better identify axillary lymph node metastasis for breast cancer patients when combined with other lymph node features. SWE is a reliable method for the objective quantification of tissue stiffness of axillary lymph nodes.
ADVANCES IN KNOWLEDGE: This study presents physiological reference values for tissue stiffness by examining the axillary lymph nodes with SWE in 175 women with sonomorphologically unsuspicious lymph nodes.
引用
- Togawa, Binder, Feisst, et al. Shear wave elastography as a supplemental tool in the assessment of unsuspicious axillary lymph nodes in patients undergoing breast ultrasound examination. Br J Radiol. 2022. PMID: 36000742. doi:10.1259/bjr.20220372
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。