文献速递神经MR

新型三维磁共振指纹成像放射组学在成人脑肿瘤中的可行性研究

Novel 3D magnetic resonance fingerprinting radiomics in adult brain tumors: a feasibility study.
PubMed 文献 · Eur Radiol · 2022-08-24

本研究对78例初诊成人脑肿瘤患者行3D MRF采集,对强化肿瘤区、非强化肿瘤区和瘤周水肿区进行放射组学分析。结果显示,MRF T1和T2特征可区分胶质母细胞瘤与脑转移瘤,并可区分胶质瘤级别及IDH1突变状态,强化肿瘤区T1特征与总生存相关。

要点

  • 3D MRF放射组学特征有助于鉴别胶质母细胞瘤与脑转移瘤。
  • MRF特征可区分胶质瘤级别(2级 vs 4级、3级 vs 4级),但2级与3级间无差异。
  • 强化肿瘤区MRF T1特征与胶质瘤患者总生存相关。

诊断标准与关键数值

  • 强化肿瘤区多个MRF T1和T2特征可区分胶质母细胞瘤与脑转移瘤(AUC未报告)。
  • MRF放射组学特征可区分IDH1突变型与野生型胶质瘤(AUC未报告)。
  • 强化肿瘤区放射组学T1特征与胶质瘤总生存相关(p < 0.05)。

局限性

  • 样本量较小(78例),为单中心可行性研究。
  • 2级与3级胶质瘤间未发现差异。
  • 未报告AUC等诊断效能数值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To test the feasibility of using 3D MRF maps with radiomics analysis and machine learning in the characterization of adult brain intra-axial neoplasms.

METHODS: 3D MRF acquisition was performed on 78 patients with newly diagnosed brain tumors including 33 glioblastomas (grade IV), 6 grade III gliomas, 12 grade II gliomas, and 27 patients with brain metastases. Regions of enhancing tumor, non-enhancing tumor, and peritumoral edema were segmented and radiomics analysis with gray-level co-occurrence matrices and gray-level run-length matrices was performed. Statistical analysis was performed to identify features capable of differentiating tumors based on type, grade, and isocitrate dehydrogenase (IDH1) status. Receiver operating curve analysis was performed and the area under the curve (AUC) was calculated for tumor classification and grading. For gliomas, Kaplan-Meier analysis for overall survival was performed using MRF T1 features from enhancing tumor region.

RESULTS: Multiple MRF T1 and T2 features from enhancing tumor region were capable of differentiating glioblastomas from brain metastases. Although no differences were identified between grade 2 and grade 3 gliomas, differentiation between grade 2 and grade 4 gliomas as well as between grade 3 and grade 4 gliomas was achieved. MRF radiomics features were also able to differentiate IDH1 mutant from the wild-type gliomas. Radiomics T1 features for enhancing tumor region in gliomas correlated to overall survival (p < 0.05).

CONCLUSION: Radiomics analysis of 3D MRF maps allows differentiating glioblastomas from metastases and is capable of differentiating glioblastomas from metastases and characterizing gliomas based on grade, IDH1 status, and survival.

KEY POINTS: • 3D MRF data analysis using radiomics offers novel tissue characterization of brain tumors. • 3D MRF with radiomics offers glioma characterization based on grade, IDH1 status, and overall patient survival.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Tippareddy, Onyewadume, Sloan, et al. Novel 3D magnetic resonance fingerprinting radiomics in adult brain tumors: a feasibility study. Eur Radiol. 2022. PMID: 35999374. doi:10.1007/s00330-022-09067-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。