文献速递神经PETMRCT

68Ga-PSMA PET对胶质母细胞瘤放疗靶区勾画的附加价值

Is there any additional benefit of 68Ga-PSMA PET on radiotherapy target volume definition in patients with glioblastoma?
PubMed 文献 · Br J Radiol · 2022-09-20

本研究回顾性分析10例胶质母细胞瘤患者,比较基于术前MRI与68Ga-PSMA PET/MRI定义的放疗靶区体积。BTV较GTV平均大47%(p=0.03),但给予相同CTV外放后,CTV1与CTV2、PTV1与PTV2在大小及空间相似性上无显著差异。68Ga-PSMA PET可能有助于定义非强化肿瘤部分及复发肿瘤体积。

要点

  • 68Ga-PSMA PET所定义BTV较MRI强化区GTV平均大47%,差异有统计学意义。
  • 给予相同CTV外放后,基于MRI与PET的CTV/PTV体积及空间相似性无显著差异。
  • PSMA PET可能辅助识别非强化肿瘤部分及复发肿瘤靶区,但需进一步验证。

局限性

  • 回顾性研究,样本量仅10例。
  • 单中心设计,结果需外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the contribution of 68Gallium (68Ga)-PSMA (prostate-specific membrane antigen) positron emission tomography (PET) in defining radiotherapy (RT) target volume for glioblastoma and to compare the target volumes defined by Magnetic Resonance Imaging (MRI).

METHODS: RT planning Computed Tomography (CT) images were fused separately with pre-operative MRI and PET/MRI images of 10 glioblastoma patients, retrospectively. The contrast-enhanced area in T1 weighted MRI was contoured as gross tumor volume (GTV) and clinical target volume (CTV1) was obtained by including the cavity and T2/FLAIR hyperintense areas after giving a margin of 2 cm to the GTV. 68Ga-PSMA uptake area was contoured as biological tumor volume (BTV) and CTV2 was obtained with a margin of 2 cm to BTV. Planning target volumes (PTVs) were created with the 3 mm added to the CTVs. Conformity index (CI), dice similarity coefficient (DSC) and overlap volume (OV) were calculated by obtaining the intersection and union volumes. Volumetric comparison, similarity and overlap analyzes were performed statistically by Wilcoxon signed rank and One sample t-test.

RESULTS: The median GTV was 21,96 cc (1,04 - 82,04) and BTV was 25,58 cc (2,43 - 99,47). BTV was on average 47% larger than GTV which was statistically significant (p = 0.03). For GTV-BTV, CTV1-CTV2 and PTV1-PTV2; mean values of CI were 0,56, 0,76 and 0,76; DSC were 0,70, 0,86 and 0,86; OV were 0,88, 0,94 and 0,94, respectively. There was no significant difference on size and spatial similarity between CTV1 and CTV2, PTV1 and PTV2.

CONCLUSION: Altough BTV was larger than GTV, this significance was lost while we gave the same CTV margin including the peripheral edema. It seems that it may help to improve defining non-enhancing tumor part and also recurrent tumor volume.

ADVANCES IN KNOWLEDGE: Recent studies have focused on the role of 68Ga-PSMA PET in imaging of glial tumors. It has been observed that 68Ga-PSMA PET can clearly define the tumor borders and it can be beneficial in target volume delineation, especially in reirradiation of recurrent tumors.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Şahin, Akgun, Sirolu, et al. Is there any additional benefit of 68Ga-PSMA PET on radiotherapy target volume definition in patients with glioblastoma? Br J Radiol. 2022. PMID: 35993417. doi:10.1259/bjr.20220049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。