文献速递胸部CT

生成对抗网络重建提升低剂量胸部CT图像质量与肺结节检出

Improving image quality and lung nodule detection for low-dose chest CT by using generative adversarial network reconstruction.
PubMed 文献 · Br J Radiol · 2022-08-22

研究基于200例标准剂量CT模拟的低剂量CT训练两种生成对抗网络去噪模型(Dir和Res),并在体模及95例胸部低剂量CT上测试。两种模型均可降低图像噪声,Res模型在图像质量评分和肺结节检出敏感度上优于Dir模型和低剂量CT。

要点

  • Res去噪模型可降低低剂量胸部CT图像噪声并减少伪影。
  • Res模型肺结节检出敏感度高于Dir模型和低剂量CT。
  • 不同学习目标的GAN模型去噪效果存在差异。

核心结论

  • 两种GAN去噪模型均能有效降低胸部低剂量CT的图像噪声。
  • Res去噪模型的图像质量评分和结节检出能力优于Dir模型及低剂量CT。

研究设计与样本

  • 训练阶段使用200例标准剂量CT模拟的低剂量CT图像,Dir模型以标准剂量CT图像为目标,Res模型以标准剂量与低剂量CT的残差为目标。
  • 测试阶段纳入体模和95例胸部低剂量CT(均来自训练数据之外)评估图像质量与肺结节检出能力。
  • 参考标准为两名阅片者的结节检出结果,原文未报告具体参考标准细节。

关键影像表现/征象

  • 体模图像中,Res和Dir模型的结构相似性和峰值信噪比均高于低剂量CT。
  • Res模型的标准差最低。
  • 患者图像中,两种模型的图像噪声和质量均优于低剂量CT。
  • Res模型的伪影少于低剂量CT。

诊断标准与关键数值

  • 两名阅片者对低剂量CT、Res模型和Dir模型的肺结节诊断敏感度分别为72/77%、79/83%和72/79%。

临床应用与阅片要点

  • Res去噪模型有望在低剂量胸部CT中降低噪声并提高肺结节检出率。
  • 不同GAN学习目标对图像质量和结节检出有影响,Res模型表现更优。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the improvement of two denoising models with different learning targets (Dir and Res) of generative adversarial network (GAN) on image quality and lung nodule detectability in chest low-dose CT (LDCT).

METHODS: In training phase, by using LDCT images simulated from standard dose CT (SDCT) of 200 participants, Dir model was trained targeting SDCT images, while Res model targeting the residual between SDCT and LDCT images. In testing phase, a phantom and 95 chest LDCT, exclusively with training data, were included for evaluation of imaging quality and pulmonary nodules detectability.

RESULTS: For phantom images, structural similarity, peak signal-to-noise ratio of both Res and Dir models were higher than that of LDCT. Standard deviation of Res model was the lowest. For patient images, image noise and quality of both two models, were better than that of LDCT. Artifacts of Res model was less than that of LDCT. The diagnostic sensitivity of lung nodule by two readers for LDCT, Res and Dir model, were 72/77%, 79/83% and 72/79% respectively.

CONCLUSION: Two GAN denoising models, including Res and Dir trained with different targets, could effectively reduce image noise of chest LDCT. The image quality evaluation scoring and nodule detectability of Res denoising model was better than that of Dir denoising model and that of hybrid IR images.

ADVANCES IN KNOWLEDGE: The GAN-trained model, which learned the residual between SDCT and LDCT images, reduced image noise and increased the lung nodule detectability by radiologists on chest LDCT. This demonstrates the potential for clinical benefit.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Cao, Mao, Qin, et al. Improving image quality and lung nodule detection for low-dose chest CT by using generative adversarial network reconstruction. Br J Radiol. 2022. PMID: 35994298. doi:10.1259/bjr.20210125

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。