文献速递头颈骨肌MRCT

压缩感知增强3D梯度回波重建图像在下颌骨癌诊断中的价值:与CT及组织病理学对照

Usefulness of reconstructed images of Gd-enhanced 3D gradient echo sequences with compressed sensing for mandibular cancer diagnosis: comparison with CT images and histopathological findings.
PubMed 文献 · Eur Radiol · 2022-08-20

本研究回顾性纳入24例下颌骨鳞状细胞癌患者,对比压缩感知3D T1 turbo field echo(CS-3D-T1TFE)与MDCT对骨侵犯和软组织侵犯的显示,并以组织病理为金标准验证。结果显示CS-3D-T1TFE的观察者间一致性和与病理的相关性均较高,可能解决传统MRI对病变范围高估的问题。

要点

  • CS-3D-T1TFE重建图像对下颌骨癌骨侵犯的观察者间一致性近乎完美,优于MDCT。
  • CS-3D-T1TFE图像评估与病理评估在20例中15例一致,呈高相关性(r>0.8)。
  • CS-3D-T1TFE对软组织侵犯各项指标的观察者间一致性均高于MDCT。

核心结论

  • CS-3D-T1TFE重建图像能准确描绘下颌骨癌侵犯范围,临床有用,并可能解决传统MRI对病变范围高估的问题。

研究设计与样本

  • 回顾性研究,纳入24例术前接受CS-3D-T1TFE和MDCT检查的下颌骨鳞状细胞癌患者,其中20例有手术病理结果。
  • 两种检查均重建0.5 mm厚冠状面及垂直于和平行于牙列方向的0.5 mm厚层面图像。
  • 由两名放射科医生按皮质骨、松质骨和下颌管三分类评估骨侵犯,采用加权kappa评估观察者间一致性,并与病理科医生的组织病理学评估用Pearson相关系数分析相关性。

关键影像表现/征象

  • CS-3D-T1TFE评估骨侵犯的观察者间一致性近乎完美,MDCT为显著一致。
  • 两名观察者的图像评估与病理评估在20例中15例一致,呈高相关性(r>0.8)。
  • CS-3D-T1TFE对下颌舌骨肌、龈颊沟和咀嚼间隙侵犯的所有测量指标观察者间一致性均高于MDCT。

诊断标准与关键数值

  • 骨侵犯按皮质骨、松质骨和下颌管三分类标准评估。
  • 软组织侵犯通过诊断是否存在下颌舌骨肌、龈颊沟和咀嚼间隙侵犯来评估。

临床应用与阅片要点

  • 日常阅片可关注CS-3D-T1TFE重建的0.5 mm薄层冠状面及平行/垂直于牙列层面,用于精细评估下颌骨皮质、松质骨及下颌管侵犯。
  • CS-3D-T1TFE观察者间一致性高,可能减少传统MRI对肿瘤范围的高估,报告时可结合多平面重建判断软组织侵犯。

局限性

  • 回顾性研究,样本量较小(24例,其中20例有病理),结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the delineation of mandibular cancer by 3D T1 turbo field echo with compressed SENSE (CS-3D-T1TFE) images and MDCT images, and to compare both sets of images with histopathological findings, as the gold standard, to validate the accuracy and clinical usefulness of CS-3D-T1TFE reconstruction.

METHODS: Twenty-four patients with mandibular squamous cell carcinoma (SCC) who underwent MRI including CS-3D-T1TFE and MDCT examinations before surgery were retrospectively included. For both examinations, 0.5-mm-thick coronal plane images and 0.5-mm-thick plane images perpendicular and parallel to the dentition were constructed. Two radiologists rated bone invasion in three categories indexed by cortical bone, cancellous bone, and mandibular canal (MC), and inter-rater agreement was assessed by weighted kappa statistics. In 20 of the 24 patients who underwent surgery, the correlation of bone invasion with the histopathological evaluation by pathologists was assessed using Pearson's correlation coefficient. Soft-tissue invasion was assessed by diagnosing the presence of invasion into the mylohyoid muscle, gingivobuccal fold, and masticator space, and inter-rater agreement was assessed by kappa statistics.

RESULTS: The interobserver agreement for bone invasion assessment was almost perfect with CS-3D-T1TFE and substantial with MDCT. The image evaluations by both observers agreed with the pathological evaluations in 15 of the 20 cases, showing high correlation (r > 0.8). CS-3D-T1TFE also showed higher inter-rater agreement than MDCT for all measures of soft-tissue invasion.

CONCLUSIONS: CS-3D-T1TFE reconstructed images were clinically useful in accurately depicting the extent of mandibular cancer invasion and potentially solving the problem of lesion overestimation associated with conventional MRI.

KEY POINTS: • Reconstructed CS-3D-T1TFE images were useful for the diagnosis of mandibular cancer. • CS-3D-T1TFE images showed higher inter-rater agreement than MDCT and high correlation with pathological findings. • CS-3D-T1TFE images may solve the problem of overestimation of the tumor extent, which has been associated with MRI in the past.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kami, Chikui, Togao, et al. Usefulness of reconstructed images of Gd-enhanced 3D gradient echo sequences with compressed sensing for mandibular cancer diagnosis: comparison with CT images and histopathological findings. Eur Radiol. 2022. PMID: 35986770. doi:10.1007/s00330-022-09075-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。