文献速递泌尿生殖腹部MR

3T酰胺质子转移成像用于膀胱癌的可行性初步研究

The feasibility of amide proton transfer imaging at 3 T for bladder cancer: a preliminary study.
PubMed 文献 · Clin Radiol · 2022-08-16

本研究通过牛血清白蛋白体模实验优化膀胱癌APT成像参数,并在11名健康志愿者和18例膀胱癌患者中评估观察者间一致性。结果显示最佳方案为1次激发、饱和功率2 μT、饱和时间2 s,膀胱癌组织MTRasym显著高于正常膀胱壁。

要点

  • 3T APT成像参数优化为1次激发、饱和功率2 μT、饱和时间2 s。
  • 膀胱癌组织MTRasym(1.81±0.71)显著高于健康志愿者膀胱壁(0.34±0.12)和患者正常膀胱壁(0.31±0.11)。
  • APT信号强度随蛋白浓度升高和pH降低而增加。

关键影像表现/征象

  • 膀胱癌组织MTRasym为1.81±0.71,健康志愿者膀胱壁为0.34±0.12,患者正常膀胱壁为0.31±0.11。
  • 健康志愿者膀胱壁与患者正常膀胱壁MTRasym无显著差异。
  • APT信号强度随蛋白浓度增加而升高,随pH降低而升高。

诊断标准与关键数值

  • 最佳APT扫描方案:1次激发、饱和功率2 μT、饱和时间2 s。
  • MTRasym在全部受试者中显示良好一致性。

临床应用与阅片要点

  • 可参考优化参数(1次激发、饱和功率2 μT、饱和时间2 s)进行3T膀胱APT成像。
  • 膀胱癌组织MTRasym升高,可与正常膀胱壁区分。

局限性

  • 初步研究,样本量小(11名健康志愿者和18例膀胱癌患者)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the optimal amide proton transfer (APT) imaging parameters for bladder cancer (BCa), the influence of different protein concentrations and pH values on APT imaging, and to establish the reliability of APT imaging in healthy volunteers and patients with BCa.

MATERIALS AND METHODS: The optimal APT imaging parameters for BCa were experimentally optimised using cross-linked bovine serum albumin (BSA) phantoms. BSA phantoms were scanned with different values for the saturation power, saturation duration and number of excitations. Meanwhile, BSA phantoms containing different protein concentrations and solutions of different pH levels were scanned. The interobserver agreement of the asymmetric magnetisation transfer ratio (MTRasym) was assessed in 11 healthy volunteers and 18 patients with BCa.

RESULTS: The optimal scanning scheme consisted of 1 excitation, a saturation power of 2 μT, and a saturation time of 2 s. The APT signal intensity increased as the protein concentration increased and as the pH decreased. The MTRasym showed good concordance for all subjects. The MTRasym of BCa tissue was significantly higher (1.81 ± 0.71) than that of bladder wall in healthy volunteers (0.34 ± 0.12) and normal bladder wall in patients with BCa (0.31 ± 0.11; p<0.001). There was no significant difference between the bladder wall of healthy volunteers and the normal bladder wall of patients with BCa.

CONCLUSION: APT imaging showed potential value for application in BCa.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Xu, Xiang, et al. The feasibility of amide proton transfer imaging at 3 T for bladder cancer: a preliminary study. Clin Radiol. 2022. PMID: 35985845. doi:10.1016/j.crad.2022.07.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。