弥散张量成像鉴别肝脏良恶性局灶性病变的价值
前瞻性纳入49例患者共74个肝脏局灶性病变,行动态MRI、DWI及DTI检查,由两名放射科医师独立测量ADC、FA及MD值。结果显示DTI的MD和FA在鉴别良恶性及区分HCC与非HCC恶性病变方面优于DWI的ADC,FA>0.38是HCC的独立预测因子。
要点
- DTI的MD和FA鉴别肝脏良恶性病变优于DWI的ADC。
- FA>0.38是区分HCC与非HCC恶性病变的独立预测因子。
- 血管瘤ADC和MD显著高于恶性病变,FA显著低于恶性病变。
关键影像表现/征象
- 血管瘤的平均ADC和MD值显著高于HCC和非HCC恶性病变。
- 血管瘤的平均FA值显著低于非HCC恶性病变和HCC。
诊断标准与关键数值
- ADC≤1.17×10-3 mm2/s、MD≤1.71×10-3 mm2/s、FA>0.29分别是鉴别恶性和良性HFL的极好指标。
- ADC>1.03×10-3 mm2/s和MD>1.12×10-3 mm2/s分别是很好的鉴别指标。
- FA>0.38是鉴别HCC与非HCC恶性病变的极好指标,且是唯一有统计学意义的独立预测因子,FA>0.38的病变为HCC的比值比为34倍。
- 观察者间一致性极好,ICC>0.9。
临床应用与阅片要点
- 在肝脏局灶性病变的MRI评估中,可补充DTI序列测量MD和FA,辅助DWI的ADC鉴别良恶性。
- FA>0.38提示HCC可能性大,需结合动态增强表现综合判断。
- 注意血管瘤的ADC和MD偏高而FA偏低,与恶性病变表现相反。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic accuracy of diffusion tensor imaging (DTI) in the characterization of hepatic focal lesions (HFLs) and compare it to diffusion-weighted imaging (DWI).
METHODS: Prospective analysis was done for 49 patients (23 male and 26 female) with 74 HFLs who underwent dynamic MRI, DWI, and DTI. Apparent diffusion coefficient (ADC) values from DWI, fractional anisotropy (FA) values, and mean diffusivity (MD) values from DTI were measured by two independent radiologists. HFLs were classified into benign and malignant HFLs; the latter were subdivided into HCC and non-HCC lesions. Binary logistic regression was performed to analyze the associations between the DTI parameters and the distinction of malignant lesions.
RESULTS: The ADC, MD, and FA at cutoff values of ≤ 1.17 × 10-3 mm2/s, ≤ 1.71 × 10-3 mm2/s, and > 0.29, respectively, are excellent discriminators for differentiating malignant and benign HFLs. The mean ADC and MD values of hemangiomas were significantly higher than HCC and non-HCC malignant lesions. In contrast, the mean FA values of hemangiomas were significantly lower than those of non-HCC malignant lesions and HCCs. The ADC and MD were very good discriminators at cutoff values of > 1.03 × 10-3 mm2/s and > 1.12 × 10-3 mm2/s, respectively. The FA at a cutoff value > 0.38 is an excellent discriminator for HCC versus non-HCC malignant lesions. Only FA value > 0.38 was a statistically significant independent predictor of HCC versus non-HCC lesions among the three parameters. There was an excellent inter-observer agreement with ICC > 0.9.
CONCLUSION: MD and FA of DTI are non-invasive, very good, and excellent discriminators superior to ADC measured by DWI for the differentiation of HFLs.
KEY POINTS: • The ADC, MD, and FA at cutoff values of ≤ 1.17 × 10-3 mm2/s, ≤ 1.71 × 10-3 mm2/s, and > 0.29, respectively, are excellent discriminators for differentiating malignant and benign HFLs. • The mean ADC and MD values of hemangiomas were significantly higher than those of HCC and non-HCC malignant lesions. In contrast, the mean FA values of hemangiomas were significantly lower than those of non-HCC malignant lesions and HCCs, respectively. • Multivariate regression analysis revealed that only FA value > 0.38 was a statistically significant independent predictor of HCC vs. non-HCC lesions. A lesion with FA > 0.38 has 34 times higher odds of being HCC rather than non-HCC lesions.
引用
- Saleh, Elmokadem, Razek, et al. Utility of diffusion tensor imaging in differentiating benign from malignant hepatic focal lesions. Eur Radiol. 2022. PMID: 35982336. doi:10.1007/s00330-022-09091-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。