文献速递甲状腺与浅表儿科影像US

2021版韩国甲状腺影像报告和数据系统在儿童甲状腺结节中的诊断效能

Diagnostic performance of the 2021 Korean thyroid imaging reporting and data system in pediatric thyroid nodules.
PubMed 文献 · Eur Radiol · 2022-08-17

模拟分析显示2021版K-TIRADS准确率均高于2016版;K-TIRADS 5活检阈值0.5 cm较1.0 cm特异度降低但敏感度和准确率升高;K-TIRADS 4阈值1.0-1.5 cm较1.0 cm特异度升高。在小结节中2021版较2016版敏感度更高且保持特异度,在大结节中特异度更高且保持敏感度。

要点

  • 儿童甲状腺结节评估中2021版K-TIRADS准确率优于2016版。
  • K-TIRADS 5活检阈值降至0.5 cm可提高敏感度但降低特异度。
  • 小结节中2021版敏感度更高且特异度相当,大结节中特异度更高且敏感度相当。

局限性

  • 回顾性研究设计。
  • 单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic performance of 2021 K-TIRADS biopsy criteria for detecting malignant thyroid nodules in a pediatric population, making comparisons with 2016 K-TIRADS.

METHODS: This retrospective study included pediatric patients with histopathologically confirmed diagnoses. The diagnostic performance of 2021 K-TIRADS was compared with that of 2016 K-TIRADS. Simulation studies were performed by changing biopsy cut-off sizes for K-TIRADS 5 to 1.0 cm (K-TIRADS5-1.0cm) and 0.5 cm (K-TIRADS5-0.5cm), and for K-TIRADS 4 to 1.0 cm (K-TIRADS4-1.0cm) and 1.0-1.5 cm (K-TIRADS4-1.0~1.5cm). Subgroup analysis was performed in small (< 1.5 cm) and large nodules (≥ 1.5 cm).

RESULTS: Two hundred seventy-seven thyroid nodules (54.9% malignant) from 221 pediatric patients were analyzed. All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. Compared with 2021 K-TIRADS5-1.0cm, 2021 K-TIRADS5-0.5cm showed lower specificity (51.6% vs. 47.9%; p = 0.004) but higher sensitivity (77.2% vs. 90.3%; p < 0.001) and accuracy (62.7% vs. 68.9%; p < 0.001). Compared with 2021 K-TIRADS4-1.0cm, 2021 K-TIRADS4-1.0~1.5cm showed higher specificity (44.9% vs. 47.9%; p = 0.018) without significant difference in other diagnostic measures. Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity (34.0% vs. 67.3%; p < 0.001) while maintaining specificity (89.4% vs. 88.2%; p = 0.790) in small nodules, and higher specificity (5.9% vs. 25.4%; p < 0.001) while maintaining sensitivity (100% vs. 98.7%; p = 0.132) in large nodules.

CONCLUSIONS: In pediatric patients, 2021 K-TIRADS showed superior diagnostic accuracy to 2016 K-TIRADS, especially with a biopsy cut-off of 0.5 cm for K-TIRADS 5 and 1.0-1.5 cm for K-TIRADS 4.

KEY POINTS: • All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. • 2021 K-TIRADS with cut-off size for K-TIRADS 5 of 0.5 cm showed lower specificity but higher sensitivity and accuracy than that of 1.0 cm. • Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity while maintaining specificity in small nodules, and higher specificity while maintaining sensitivity in large nodules.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim, Yoon, Baek, et al. Diagnostic performance of the 2021 Korean thyroid imaging reporting and data system in pediatric thyroid nodules. Eur Radiol. 2022. PMID: 35976400. doi:10.1007/s00330-022-09037-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。