文献速递儿科影像骨肌技术与安全DR

疑似虐待儿童骨骼调查的有效辐射剂量

Effective radiation dose of skeletal surveys performed for suspected physical abuse.
PubMed 文献 · Pediatr Radiol · 2022-08-17

结论认为剂量较低,相当于英国约1个月背景辐射,指南变更未显著增加剂量。

要点

  • 骨骼调查有效剂量约0.19 mSv,相当于英国1个月背景辐射。
  • 现行指南初始加随访调查总剂量约0.26 mSv,仍属低剂量。
  • 指南变更后剂量无显著变化,获益大于辐射风险。

核心结论

  • 骨骼调查的估算有效剂量较低,相当于英国约1个月背景辐射,指南变更后剂量无显著变化,获益大于主要辐射风险。

诊断标准与关键数值

  • 旧版RCR指南骨骼调查总估算有效剂量为0.19 mSv。
  • 现行RCR指南初始骨骼调查估算有效剂量为0.19 mSv。

临床应用与阅片要点

  • 向家长/监护人知情同意时可告知骨骼调查辐射剂量约0.19 mSv,相当于英国约1个月背景辐射。
  • 现行指南增加随访图像后总剂量约0.26 mSv,仍属低剂量,不应因辐射顾虑省略必要检查。

局限性

  • 剂量为软件估算值而非直接测量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: A skeletal survey is an important diagnostic tool for patients presenting with suspected physical abuse. A relatively recent change in guidelines for skeletal surveys by the Royal College of Radiologists (RCR) in 2017 has led to more initial and follow-up images for these patients, which would be expected to have led to an increase in effective radiation dose.

OBJECTIVE: To estimate the effective dose following the change in guidelines and to ascertain the difference between doses before and after the change in guidelines.

MATERIALS AND METHODS: Data were collected retrospectively on children younger than 3 years old referred for skeletal surveys for suspected physical abuse at a tertiary paediatric centre. A Monte Carlo radiation patient dose simulation software, PCXMC v 2.0.1, was used to estimate the effective dose, expressed in millisieverts (mSv).

RESULTS: Sixty-eight children underwent skeletal surveys for suspected physical abuse. The total estimated effective dose for skeletal surveys with the previous RCR guidelines was found to be 0.19 mSv. For initial skeletal surveys with the current RCR guidelines, the estimated effective radiation dose was 0.19 mSv. Eighteen children had both initial and follow-up skeletal surveys as indicated by the current RCR guidelines, with an estimated effective total radiation dose of 0.26 mSv.

CONCLUSION: Skeletal surveys deliver a relatively low estimated effective radiation dose equivalent to 1 month of United Kingdom background radiation, with no significant change in dose following the change in guidelines. Therefore, the benefits of having a skeletal survey outweigh the main radiation risk. However, accurate data regarding the radiation dose are important for clinicians consenting parents/guardians for imaging in suspected physical abuse.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Sait, Havariyoun, Newman, et al. Effective radiation dose of skeletal surveys performed for suspected physical abuse. Pediatr Radiol. 2022. PMID: 35974201. doi:10.1007/s00247-022-05477-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。