文献速递神经MR

三维增强彩色图用于颅内动脉粥样硬化斑块表征

3D Enhancement Color Maps in the Characterization of Intracranial Atherosclerotic Plaques.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-08-11

本研究纳入36例颅内动脉粥样硬化所致卒中患者,行7T高分辨MR成像,采用三维斑块增强彩色图定量钆摄取,并与常规2D测量比较。结果显示责任斑块钆摄取更高,且三维方法识别责任斑块的敏感度和特异度均优于2D方法,联合斑块负荷的多变量模型敏感度83%、特异度86%。

要点

  • 三维增强彩色图可客观定量斑块钆摄取,识别责任斑块优于常规2D测量。
  • 钆摄取是识别责任斑块最准确的单项指标(OR 3.9)。
  • 联合钆摄取与斑块负荷的多变量模型敏感度83%、特异度86%。

核心结论

  • 新型三维彩色图斑块增强分析方法识别责任斑块较常规2D方法更准确,并可生成用于评估疾病进展的新指标。

研究设计与样本

  • 研究为对36例颅内动脉粥样硬化所致卒中患者行7T高分辨MR成像,分析36个责任斑块和44个非责任斑块,比较三维彩色图定量钆摄取与常规2D增强测量。

关键影像表现/征象

  • 责任斑块钆摄取高于非责任斑块(P < .001)。
  • 三维彩色图从管腔向斑块及血管壁自动延伸信号强度探针,生成斑块与载瘤血管的三维增强彩色图。

诊断标准与关键数值

  • 钆摄取计算公式为(µPlaque T1+Gd - µPlaque T1)/ SD Plaque T1。
  • 钆摄取识别责任斑块的OR为3.9(95% CI 2.1-8.3),敏感度86%、特异度71%,优于常规2D测量的70%和68%。
  • 联合钆摄取与斑块负荷的多变量模型识别责任斑块敏感度83%、特异度86%。

临床应用与阅片要点

  • 三维彩色图可自动定量斑块钆摄取,减少手动ROI采样,识别的责任斑块指标更准确。
  • 钆摄取联合斑块负荷有助于提高责任斑块识别特异性,可辅助卒中病因评估。

局限性

  • 研究仅纳入36例患者,样本量有限。
  • 采用7T高分辨MR成像,设备可及性受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: High-resolution MR imaging allows the identification of culprit symptomatic plaques after the administration of gadolinium. Current high-resolution MR imaging methods are limited by 2D multiplanar views and manual sampling of ROIs. We analyzed a new 3D method to objectively quantify gadolinium plaque enhancement.

MATERIALS AND METHODS: Patients with stroke due to intracranial atherosclerotic disease underwent 7T high-resolution MR imaging. 3D segmentations of the plaque and its parent vessel were generated. Signal intensity probes were automatically extended from the lumen into the plaque and the vessel wall to generate 3D enhancement color maps. Plaque gadolinium (Gd) uptake was quantified from 3D color maps as gadolinium uptake = (µPlaque T1 + Gd -µPlaque T1/SDPlaque T1). Additional metrics of enhancement such as enhancement ratio, variance, and plaque-versus-parent vessel enhancement were also calculated. Conventional 2D measures of enhancement were collected for comparison.

RESULTS: Thirty-six culprit and 44 nonculprit plaques from 36 patients were analyzed. Culprit plaques had higher gadolinium uptake than nonculprit plaques (P < .001). Gadolinium uptake was the most accurate metric for identifying culprit plaques (OR, 3.9; 95% CI 2.1-8.3). Gadolinium uptake was more sensitive (86% versus 70%) and specific (71% versus 68%) in identifying culprit plaques than conventional 2D measurements. A multivariate model, including gadolinium uptake and plaque burden, identified culprit plaques with an 83% sensitivity and 86% specificity.

CONCLUSIONS: The new 3D color map method of plaque-enhancement analysis is more accurate for identifying culprit plaques than conventional 2D methods. This new method generates a new set of metrics that could potentially be used to assess disease progression.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Sanchez, Raghuram, Fakih, et al. 3D Enhancement Color Maps in the Characterization of Intracranial Atherosclerotic Plaques. AJNR Am J Neuroradiol. 2022. PMID: 35953278. doi:10.3174/ajnr.A7605

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。