基于扩散加权成像的影像组学鉴别局灶型自身免疫性胰腺炎与胰腺癌
回顾性分析28例局灶型自身免疫性胰腺炎(f-AIP)和77例病理证实的胰腺导管腺癌(PDAC)患者,基于ADC图提取2D-ADCmean和纹理参数,构建支持向量机(SVM)模型。f-AIP的2D-ADCmean和3D-ADCmean均显著低于PDAC,非线性SVM联合2D-ADCmean、病灶体积和指数滤波能量在测试组AUC达96.2%。
要点
- f-AIP的ADC均值低于PDAC,可辅助鉴别。
- 非线性SVM联合ADC均值、体积和纹理特征诊断效能高。
- ADC纹理参数中指数滤波能量AUC最高但读者间一致性中等。
关键影像表现/征象
- f-AIP的2D-ADCmean为1.10-1.15×10-3 mm2/s,低于PDAC的1.29-1.33×10-3 mm2/s。
- f-AIP的3D-ADCmean为1.21-1.23×10-3 mm2/s,低于PDAC的1.41-1.43×10-3 mm2/s。
- 2D-ADCmean读者间一致性优秀(ICC=0.909),3D-ADCmean良好(ICC=0.891)。
- 纹理参数中指数滤波能量AUC最高(读者1:74.7%,读者2:81.5%),读者间一致性中等(ICC=0.707)。
诊断标准与关键数值
- 非线性SVM联合2D-ADCmean、病灶体积和指数滤波能量在测试组AUC为96.2%。
- 2D-ADCmean的ICC为0.909,3D-ADCmean的ICC为0.891,指数滤波能量的ICC为0.707。
临床应用与阅片要点
- 在胰腺局灶性病变鉴别中,可关注ADC均值降低提示f-AIP可能。
- 联合ADC均值、病灶体积和纹理特征(如指数滤波能量)可提高鉴别效能。
- 注意纹理参数读者间一致性中等,需规范分割和参数设置。
局限性
- 回顾性研究,样本量有限(28例f-AIP和77例PDAC)。
- 单中心研究,需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the parameters of support vector machine (SVM) using imaging data generated from the apparent diffusion coefficient (ADC) to differentiate between focal-type autoimmune pancreatitis (f-AIP) and pancreatic ductal adenocarcinoma (PDAC) when using SVM based on diffusion-weighted imaging.
METHODS: The 2D-ADCmean and texture parameters (16 texture features × [non-filter+17 filters]) were retrospectively segmented by 2 readers in 28 patients with f-AIP and 77 patients with pathologically proven PDAC. The diagnostic accuracy of the SVM model was evaluated by receiver operating characteristic curve analysis and calculation of the area under the curve (AUC). Interreader reliability was assessed by intraclass correlation coefficient (ICC).
RESULTS: The 2D-ADCmean and 3D-ADCmean were significantly lower in cases of f-AIP (1.10-1.15 × 10-3 mm2/s and 1.21-1.23× 10-3 mm2/s, respectively) vs PDAC (1.29-1.33 × 10-3 mm2/s and 1.41-1.43 × 10-3 mm2/s, respectively), with excellent and good interreader reliability, respectively (ICC = 0.909 and 0.891, respectively). Among the texture parameters, energy with exponential filtering yielded the highest AUC (Reader 1: 74.7%, Reader 2: 81.5%), with fair interreader reliability (ICC = 0.707). The non-linear SVM, a combination of 2D-ADCmean, object volume and exponential-energy showed an AUC value of 96.2% in the testing cohorts.
CONCLUSION: Our results suggest that non-linear SVM using a combination of 2D-ADCmean, object volume, and exponential-energy may assist in differentiating f-AIP from PDAC.
ADVANCES IN KNOWLEDGE: The radiomics based on an apparent diffusion coefficient value may assist in differentiating f-AIP from PDAC.
引用
- Shiraishi, Igarashi, Hiroaki, et al. Radiomics based on diffusion-weighted imaging for differentiation between focal-type autoimmune pancreatitis and pancreatic carcinoma. Br J Radiol. 2022. PMID: 35946923. doi:10.1259/bjr.20210456
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。