深度学习重建联合减影技术提升冠状动脉CTA支架内再狭窄诊断效能
这项前瞻性研究纳入30例患者共59枚冠状动脉支架,评估深度学习重建(DLR)、减影技术及二者联合对支架内再狭窄(≥50%狭窄)的诊断效能,以侵入性血管造影为参考标准。结果显示DLR联合减影技术获得最佳诊断性能,最高特异度达90.1%或95.5%,可指导患者选择侵入性支架评估。
要点
- DLR可增加支架内可见管腔直径,减影技术进一步改善无严重配准伪影支架的管腔显示。
- DLR联合减影技术诊断支架内再狭窄的特异度最高达90.1%(读者1)或95.5%(读者2)。
- 联合策略有助于减少支架伪影导致的假阳性,优化侵入性评估的患者筛选。
核心结论
- DLR联合减影技术对冠状动脉CTA检出支架内再狭窄(≥50%狭窄)获得最佳诊断性能。
研究设计与样本
- 前瞻性研究纳入2020年3月至2021年8月间30例冠状动脉支架患者(男22例、女8例,平均年龄63.6±7.4岁),共59枚支架。
- 采用两次屏气技术(非增强与增强采集),分别重建HIR和DLR的常规与减影图像,以侵入性血管造影为参考标准。
- 两名读者独立评估支架内再狭窄(≥50%狭窄),并模拟联合常规与减影图像的评估(根据有无严重配准伪影选择)。
关键影像表现/征象
- DLR的最大可见支架内管腔直径高于HIR(2.3±0.5 mm vs 2.1±0.5 mm,p<.001)。
- 在无严重配准伪影的支架中,减影DLR的最大可见管腔直径高于常规DLR(3.0±0.5 mm vs 2.4±0.5 mm,p<.001)。
- 59枚支架中32枚存在严重配准伪影。
诊断标准与关键数值
- 支架内再狭窄定义为≥50%狭窄,以侵入性血管造影为参考标准。
- 读者1:各方法敏感度均为62.5%,DLR联合减影特异度最高90.1%、PPV 71.4%、NPV 87.0%、准确率83.3%。
- 读者2:各方法敏感度均为50.0%,HIR或DLR联合减影特异度均95.5%、PPV均80.0%、NPV均84.0%、准确率均83.3%。
临床应用与阅片要点
- 冠脉CTA评估支架时建议联合DLR与减影技术,以减少支架伪影所致假阳性。
- 存在严重配准伪影时联合策略的增益可能受限,需注意甄别。
局限性
- 样本量较小(30例患者、59枚支架),可能影响结果外推。
- 单中心前瞻性设计,需多中心验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. Coronary CTA with hybrid iterative reconstruction (HIR) is prone to false-positive results for in-stent restenosis due to stent-related blooming artifact. OBJECTIVE. The purpose of this study is to assess the impact of deep learning reconstruction (DLR), subtraction images, and the combination of DLR and subtraction images on the diagnostic performance of coronary CTA for the detection of in-stent restenosis. METHODS. This prospective study included patients with coronary stents who underwent coronary CTA between March 2020 and August 2021. CTA used a technique with two breath-holds (noncontrast and contrast-enhanced acquisitions). Conventional and subtraction images were reconstructed for HIR and DLR. The maximum visible instent lumen diameter was measured. Two readers independently evaluated images for in-stent restenosis (≥ 50% stenosis). A simulated assessment of combined conventional and subtraction images was generated, reflecting assessment of conventional and subtraction images in the presence or absence of severe misregistration artifact, respectively. Invasive angiography served as reference standard. RESULTS. The study enrolled 30 patients (22 men and eight women; mean age, 63.6 ± 7.4 [SD] years) with a total of 59 stents; severe misregistration artifact was present for 32 stents. Maximum visible in-stent lumen diameter was higher for DLR than for HIR (2.3 ± 0.5 vs 2.1 ± 0.5 mm, p < .001), and among stents without severe misregistration artifact, it was higher for subtraction than conventional DLR (3.0 ± 0.5 vs 2.4 ± 0.5, p < .001). Among conventional CTA with HIR, conventional CTA with DLR, combination (conventional and subtraction) approach with HIR, and combination (conventional and subtraction) approach with DLR, the highest patient-level diagnostic performance measures were as follows: for reader 1, sensitivity was identical (62.5%), specificity was highest for combination with DLR (90.1%), PPV was highest for combination with DLR (71.4%), NPV was highest for combination with DLR (87.0%), and accuracy was highest for combination with DLR (83.3%); for reader 2, sensitivity was identical (50.0%), specificity was highest for combination with HIR or DLR (both 95.5%), PPV was highest for combination with HIR or DLR (both 80.0%), NPV was highest for combination with HIR or DLR (84.0%), and accuracy was highest for combination with HIR or DLR (both 83.3%). CONCLUSION. The combined DLR and subtraction technique yielded optimal diagnostic performance for detecting in-stent restenosis by coronary CTA. CLINICAL IMPACT. The described technique could guide patient selection for invasive coronary stent evaluation.
引用
- Xu, Yi, Xu, et al. Coronary Artery Stent Evaluation by CTA: Impact of Deep Learning Reconstruction and Subtraction Technique. AJR Am J Roentgenol. 2022. PMID: 35946861. doi:10.2214/AJR.22.27983
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。