T2加权Dixon MRI序列中软骨下水肿对中轴型脊柱关节炎骶髂关节侵蚀评估的影响
本研究纳入20例中轴型脊柱关节炎患者,由两名肌骨放射科医生独立评分T2W Dixon序列(同相位、反相位、脂肪-only)对骶髂关节8个象限侵蚀的诊断效能,以T1W序列为参考标准。结果显示脂肪-only和同相位图像诊断效能相似(AUC 0.857-0.902和0.828-0.868),优于反相位图像(AUC 0.613-0.658)。软骨下水肿存在时,各图像集的特异度和AUC均降低,结论为活动性骶髂关节炎的软骨下水肿会降低T2W Dixon MRI对侵蚀的诊断准确性。
要点
- 脂肪-only和同相位图像诊断骶髂关节侵蚀的AUC较高,反相位较低。
- 软骨下水肿阳性组各图像集的特异度和AUC均低于水肿阴性组。
- 反相位图像观察者间信度仅中等(k=0.417),脂肪-only和同相位信度较好。
核心结论
- 活动性骶髂关节炎的软骨下水肿会降低T2W Dixon MRI图像对骶髂关节侵蚀检测的诊断准确性。
研究设计与样本
- 回顾性纳入20例确诊中轴型脊柱关节炎患者,2019年12月至2021年3月在一家三级转诊中心行MRI检查。
- 两名肌骨放射科医生独立评分T2W Dixon序列的同相位、反相位和脂肪-only图像上骶髂关节8个象限的侵蚀。
- 以T1W序列为参考标准,计算敏感度、特异度和ROC曲线下面积(AUC),并用Cohen kappa系数评估观察者内和观察者间信度。
关键影像表现/征象
- 脂肪-only和同相位图像诊断侵蚀的AUC分别为0.857-0.902和0.828-0.868,反相位图像为0.613-0.658。
- 脂肪-only和同相位图像观察者间信度分别为k=0.747和k=0.712(显著),反相位为k=0.417(中等)。
- 所有图像的观察者内信度几乎完美。
- 亚组分析中,水肿阳性组各图像集的特异度和AUC均低于水肿阴性组。
- 水肿阳性组反相位图像观察者间信度轻微,水肿阴性组为中等;脂肪-only和同相位在两亚组均为显著。
诊断标准与关键数值
- 以T1W序列为参考标准,脂肪-only图像诊断骶髂关节侵蚀的AUC为0.857-0.902。
- 同相位图像诊断骶髂关节侵蚀的AUC为0.828-0.868。
- 反相位图像诊断骶髂关节侵蚀的AUC为0.613-0.658。
临床应用与阅片要点
- 阅片时优先选择脂肪-only或同相位图像评估骶髂关节侵蚀,反相位图像诊断准确性较低。
- 存在软骨下水肿时需警惕侵蚀诊断特异度下降,避免过度诊断。
局限性
- 样本量仅20例,来自单中心,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the effect of subchondral oedema in T2-weighted Dixon magnetic resonance imaging (MRI) sequence evaluation of sacroiliac joint erosion in patients with axial spondyloarthropathy.
MATERIALS AND METHODS: Twenty patients diagnosed with axial spondyloarthritis underwent MRI at a tertiary referral centre from December 2019 to March 2021 were included. In-phase, opposed-phase and fat-only images were scored by two musculoskeletal radiologists independently for the presence of erosions in eight sacroiliac joint quadrants. Sensitivity, specificity and areas under the curve (AUC) of the receiver operating characteristic curve were determined using T1W sequence as reference standard. Intra-observer and interobserver reliability were calculated using Cohen's kappa coefficient.
RESULTS: The diagnostic performance of fat-only and in-phase images were similar (AUC 0.857-0.902 and 0.828-0.868) and better than opposed-phase images (AUC 0.613-0.658). The interobserver reliability of fat-only and in-phase images were substantial (k = 0.747 and 0.712), and moderate for opposed-phase images (k = 0.417). Intra-observer reliability was almost perfect for all the images. In the subgroup analysis, the specificity and AUC for oedema-positive group were lower than oedema-negative group in all image sets. Interobserver reliability was substantial for fat-only and in-phase images in both groups, but slight and moderate for the opposed-phase oedema-positive and negative groups, respectively.
CONCLUSION: The presence of subchondral oedema in active sacroiliitis decreased the diagnostic accuracy of sacroiliac joint erosion detection on T2W Dixon MRI images.
引用
- Chien, Lee, Chung, et al. The effect of subchondral oedema in T2-weighted Dixon MRI sequence evaluation of sacroiliac joint erosion in axial spondyloarthropathy. Clin Radiol. 2022. PMID: 35940928. doi:10.1016/j.crad.2022.06.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。