急诊超声专家共识检查表的研制:eFAST检查表
本研究采用基于ACEP影像指南的全国性急诊超声专家共识方法,经10名专家两轮迭代制定eFAST检查表。在24名模拟环境下的住院医师中评估,两名盲法评估者间kappa为0.670,高年资与低年资住院医师检查表表现差异显著(-8.1%,p=0.004)。
要点
- eFAST检查表经10名专家两轮迭代达成共识,以ACEP影像指南为主要参考。
- 检查表评估者间信度中等(kappa=0.670),胸部和部分腹部项目一致性近完美或完美。
- 高年资住院医师检查表表现显著优于低年资(差异-8.1%,p=0.004)。
局限性
- 研究仅在模拟环境中评估24名住院医师,样本量有限。
- 仅针对eFAST单一应用,其他急诊超声应用的检查表尚需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Within today's competency-based medical education, traditional set number proficiency benchmarks have been called into question. Checklists may help guide individualized training and standardized outcomes. However, multicenter expert consensus checklists based on established guidelines with supporting validity evidence have not been published for specific emergency ultrasound (EUS) applications. We describe a robust national EUS expert consensus methodology for developing a checklist for the extended focused assessment with sonography in trauma (eFAST examination).
METHODS: Utilizing the ACEP imaging compendium as a primary reference, 10 national EUS experts iteratively refined and agreed upon a final checklist. To obtain initial reliability and validity evidence, two different EUS experts blinded to resident experience then assessed 24 residents performing an eFAST in a simulated environment. Inter-rater reliability of the checklist was assessed using Cohen's kappa coefficient. Validity was assessed by comparing mean performance with the Student's t-test and discriminant ability of individual checklist items using item-total correlation.
RESULTS: The 10 EUS experts agreed on the final checklist items after two rounds of iterations. When evaluating 24 emergency medicine (EM) PGY-1 to -4 residents, the kappa correlation between two blinded EUS faculty raters was moderate at 0.670. Kappa and agreement were near-perfect or perfect in right and left chest image optimization, right upper quadrant (RUQ) probe placement, RUQ anatomy identification, and pelvic first-view anatomy identification. The difference in checklist performance between junior and senior EM residents was significant at -8.1% (p = 0.004). Identification of pelvic structures and placement of the probe for pelvic views were found to have an excellent item-total correlation with values of >0.4.
CONCLUSIONS: We have described a robust national EUS expert consensus methodology for developing an eFAST checklist based on the ACEP imaging guidelines. Based on this encouraging initial reliability and validity evidence, further research and checklist development is warranted for additional EUS applications.
引用
- Bailitz, O'Brien, McCauley, et al. Development of an expert consensus checklist for emergency ultrasound. AEM Educ Train. 2022. PMID: 35936814. doi:10.1002/aet2.10783
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。