MRI对急性膝关节脱位后外侧角结构的诊断准确性
本研究回顾性分析39例急性膝关节脱位患者的术前MRI,以手术所见为参考标准评估后外侧角(PLC)结构撕裂的诊断准确性。MRI对LCL、BFT、PT、LCC的诊断准确性分别为95%、87%、82%、92%,但MRI与手术分级的一致性从一般到中等不等。
要点
- 急性膝关节脱位时,MRI对PLC结构撕裂诊断准确性高,LCL最常受累(95%)。
- MRI与手术对PLC结构完整性分级的一致性有限,需结合临床和术中探查。
- 术前MRI应作为临床怀疑PLC不稳时的常规检查。
关键影像表现/征象
- LCL撕裂最常见,占95%(37/39)。
- 54%(21/39)的病例中四个PLC结构中有三个撕裂。
- MRI与手术一致性:BFT为substantial,LCL和PT为moderate,LCC为fair。
诊断标准与关键数值
- MRI诊断准确性:LCL 95%,BFT 87%,PT 82%,LCC 92%。
- MRI与手术分级一致性采用kappa系数:BFT substantial,LCL和PT moderate,LCC fair。
临床应用与阅片要点
- 术前MRI应仔细评估PLC各结构,尤其是LCL撕裂。
- MRI分级一致性有限,报告时应描述结构完整性而非仅诊断撕裂。
- 临床怀疑PLC不稳时,MRI是重要术前评估工具,但不能完全替代术中探查。
局限性
- 单中心回顾性研究,样本量较小(39例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the diagnostic performance of preoperative MRI in evaluating posterolateral corner (PLC) structures after acute knee dislocation (KD) and determine the correlation of MRI with operative findings for grading structure integrity.
METHODS: Acute knee (femorotibial) dislocations between 2005 and 2020 with preoperative MRI and surgical posterolateral corner repair were identified from a single academic institution. From MRI, integrity was evaluated for PLC structures: lateral collateral ligament (LCL), popliteus tendon (PT), biceps femoris tendon (BFT), and ligamento-capsular complex (LCC). Frequency of injury to each structure and number of PLC structures torn in each case were tabulated. Diagnostic performance of MRI was determined using surgery as the reference standard. Correlation between MRI and surgery for each PLC structure was determined using kappa.
RESULTS: Thirty-nine KD cases (19 right) in 39 patients (28 male) were included, with mean age of 33 years. Mechanism of injury was as follows: high energy 52%, low energy 38%, ultra-low energy 10%. LCL was most frequently torn, in 95% (37/39) of cases. Most commonly, three of four PLC structures were torn in 54% (21/39) of cases. Diagnostic accuracy of MRI was high for LCL 95%, BFT 87%, PT 82%, and LCC 92%. Correlation between MRI and surgical findings was variable: substantial for BFT, moderate for LCL and PT, and fair for LCC.
CONCLUSION: MRI has high accuracy for detecting tears of posterolateral corner stabilizers in the setting of acute KD. However, for grading structure integrity, the correlation of MRI with surgical findings is variable, ranging from fair to substantial.
KEY POINTS: • In acute knee dislocation, MRI has high diagnostic accuracy for detecting tears of posterolateral corner (PLC) structures. • Preoperative MRI should be considered by orthopedic surgeons when there is clinical concern for posterolateral corner instability following acute knee dislocation. • Although MRI is valuable in the preoperative investigation of knee dislocation, clinical assessment and intraoperative exploration may still be required for definitive diagnosis.
引用
- Rakhra, Delorme, Sanders, et al. The diagnostic accuracy of MRI for evaluating the posterolateral corner in acute knee dislocation. Eur Radiol. 2022. PMID: 35925385. doi:10.1007/s00330-022-08986-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。