金属标记物对乳腺癌MRI预测病理完全缓解诊断准确性的影响
结论认为金属标记物的存在与否及品牌类型不影响MRI预测pCR的诊断效能。
要点
- 两种常见品牌标记物(O'Twist与UltraClip)间MRI诊断效能无统计学差异。
- 阅片时需记录标记物类型及MRI各序列伪影大小,但无需因标记物存在而质疑MRI预测pCR的可靠性。
关键影像表现/征象
- 记录每例MRI序列上标记物的有无、类型及伪影大小和类型。
- 两名放射科医生盲法评估MRI上是否存在完全缓解。
诊断标准与关键数值
- 无标记物组MRI预测pCR的敏感度0.67、特异度0.90(P<0.05)。
- 两种标记物品牌(O'Twist与UltraClip)间MRI诊断效能无统计学差异。
临床应用与阅片要点
- 日常阅片应记录金属标记物的存在、类型及伪影特征,但不应因此降低对MRI预测pCR的信心。
局限性
- 标记物品牌间比较的样本量可能不足。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate if the presence of metallic markers (markers) influences the diagnostic accuracy of preoperative breast MRI for the prediction of pathological complete response (pCR) to neoadjuvant chemotherapy (NAC) in breast cancer patients.
MATERIALS AND METHODS: In this single-center, retrospective, observational study approved by the IRB of our institution, we included all consecutive patients that underwent preoperative breast MRI after completion of NAC (Mean 4,4 days ± 15,9). The presence or absence of markers, the type of markers, the size and type of artefact on each MRI sequence were recorded. Two radiologists blinded to histopathological results and to each other's findings evaluated all MRI examinations for presence or absence of complete response. Pathology was the standard of reference. Diagnostic performance of MRI for prediction of pCR in the presence or absence of markers and also between two most represented markers brands (O'Twist and UltraClip) were compared using Chi-squared tests or equivalents.
RESULTS: Ninety-three patients (mean age 48 ± 11 years) were included in this study. Nineteen of them had no markers and 74 had 108 markers. Sensitivity and specificity of MRI for the prediction of pCR were 0.73 and 0,81 for patients with and 0.67 and 0.90 for patients without markers (p < 0.05).There was no statistical difference in the performance of MRI for the two different types of markers studied.
CONCLUSION: Diagnostic performance of pre-operative MRI after NAC for the prediction of pCR did not differ statistically in the presence or absence of metallic markers nor between the two markers' brands studied.
引用
- Matthias, Clémence, Electra, et al. Diagnostic precision of breast MRI in prediction of pathological complete response: Is it influenced by the presence of metallic markers? Eur J Radiol. 2022. PMID: 35926356. doi:10.1016/j.ejrad.2022.110453
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。