文献速递骨肌技术与安全MR

零回波时间肌肉骨骼MRI:技术、优化、应用与陷阱

Zero Echo Time Musculoskeletal MRI: Technique, Optimization, Applications, and Pitfalls.
PubMed 文献 · Radiographics · 2022-07-29

本文介绍零回波时间(ZTE)成像的技术原理与优化方法,包括带宽、翻转角、视野和图像矩阵的调整;ZTE对皮质骨与软组织对比类似X线或CT,可显示撞击、撕脱与应力性骨折、关节内游离体或侵蚀、软组织钙化与骨化及骨肿瘤等;其陷阱包括关节内气体及手术材料与含铁血黄素沉积所致磁化率伪影,可通过对照其他MRI序列避免。

要点

  • ZTE序列对皮质骨与软组织提供类似X线或CT的对比,但空间分辨率仍逊于X线和CT。
  • ZTE图像需灰度反转(黑变白、白变黑)后才能获得类似X线或CT的骨与软组织对比。
  • 关节内气体、手术材料与含铁血黄素沉积可模拟钙化或骨化,需对照其他MRI序列鉴别。

核心结论

  • ZTE MRI可良好显示肌肉骨骼系统多种结构异常及疾病或愈合过程,包括需骨形态学分析的病变、撞击、撕脱与应力性骨折、关节内或关节周围游离体或侵蚀、软组织钙化与骨化以及骨肿瘤(含治疗反应)。
  • ZTE的陷阱包括关节内气体以及手术材料和含铁血黄素沉积所致磁化率伪影,可模拟钙化或骨化灶,许多情况下可通过对照其他MRI序列图像避免。

研究设计与样本

  • 本文为技术综述,介绍ZTE成像的序列设置、优化方法(带宽、翻转角、视野和图像矩阵的调整)、临床应用与陷阱,未报告样本量或参考标准。

关键影像表现/征象

  • ZTE序列采样矿化骨小梁基质尤其是皮质骨的极短T2信号,二者质子密度(PD)均低。
  • ZTE序列的PD加权使软组织之间对比度较低。
  • 经灰度反转后,ZTE图像上皮质骨与软组织之间对比优异,类似X线和CT。
  • ZTE序列具备各向同性或近各向同性三维(3D)成像能力。
  • ZTE的空间分辨率仍逊于X线和CT。

临床应用与阅片要点

  • ZTE图像的灰度需反转(黑变白、白变黑)后方可获得类似X线或CT的骨与软组织对比。
  • 优化ZTE MRI主要涉及带宽、翻转角、视野和图像矩阵的调整。
  • 3D容积渲染目前耗时且需要具备分割和手动勾画功能的后处理软件。
  • 关节内气体及手术材料、含铁血黄素沉积所致磁化率伪影可模拟钙化或骨化灶,许多情况下可通过对照其他MRI序列图像避免。

局限性

  • ZTE的空间分辨率仍逊于X线和CT。
  • 3D容积渲染目前耗时且需要具备分割和手动勾画功能的后处理软件。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Zero echo time (ZTE) imaging is an MRI technique that produces images similar to those obtained with radiography or CT. In ZTE MRI, the very short T2 signal from the mineralized trabecular bone matrix and especially cortical bone-both of which have a low proton density (PD)-is sampled in a unique sequence setup. Additionally, the PD weighting of the ZTE sequence results in less contrast between soft tissues. Therefore, along with gray-scale inversion from black to white and vice versa, ZTE imaging provides excellent contrast between cortical bone and soft tissues similar to that of radiography and CT. However, despite isotropic or near-isotropic three-dimensional (3D) imaging capabilities of the ZTE sequence, spatial resolution in this technique is still inferior to that of radiography and CT, and 3D volume renderings are currently time-consuming and require postprocessing software that features segmentation and manual contouring. Optimization of ZTE MRI mostly entails adjustments of bandwidth, flip angle, field of view, and image matrix. A wide range of structural abnormalities and disease or healing processes in the musculoskeletal system are well delineated with ZTE MRI, including conditions that involve bone-based morphometric analyses (which aid diagnosis, help prognostication, and guide surgery), impaction, avulsion and stress fractures, loose bodies or erosions in and around joints, soft-tissue calcifications and ossifications, and bone tumors (including treatment response). The pitfalls of ZTE imaging include mimics of foci of calcification or ossification such as intra-articular gas and susceptibility artifacts from surgical materials and hemosiderin deposition, which can be avoided in many instances by cross-referencing images obtained with other MRI sequences. Online supplemental material is available for this article. ©RSNA, 2022.

来源:Radiographics,查看原文。版权归原作者所有。

引用

  1. Aydıngöz, Yıldız, Ergen, et al. Zero Echo Time Musculoskeletal MRI: Technique, Optimization, Applications, and Pitfalls. Radiographics. 2022. PMID: 35904982. doi:10.1148/rg.220029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。