文献速递骨肌US

应用剪切波弹性成像测量职业与半职业女运动员下肢肌肉与肌腱的硬度

Stiffness of Muscles and Tendons of the Lower Limb of Professional and Semiprofessional Athletes Using Shear Wave Elastography.
PubMed 文献 · J Ultrasound Med · 2022-07-28

对24名健康职业女运动员(PG)与24名健康半职业女运动员(SG)行下肢肌腱与肌肉纵向剪切波弹性成像,比较硬度差异并建立参考值。PG的跟腱、比目鱼肌止点、股内侧肌及股四头肌腱硬度中位数均显著高于SG,髌腱两组无显著差异。作者认为了解这些差异对诊断肌腱病与损伤是必要的。

要点

  • 职业女运动员跟腱、比目鱼肌止点、股内侧肌硬度显著高于半职业者。
  • 髌腱硬度在职业与半职业女运动员间无显著差异(P = .25)。
  • 测量取肌腱放松位、纵向切面,可作运动医学参考值。

核心结论

  • 职业女运动员下肢肌肉及肌腱硬度高于半职业女运动员,髌腱除外;了解这些差异对诊断肌腱病与损伤是必要的;肌肉骨骼剪切波弹性成像在运动医学、康复及预防医学中可能大有益处。

研究设计与样本

  • 研究论文;对24名健康职业女运动员(PG)与24名健康半职业女运动员(SG)行双下肢肌腱及肌肉标准化剪切波弹性成像,取纵向切面、肌腱放松位,测量跟腱、比目鱼肌止点、髌腱、股四头肌腱及股内侧肌。

诊断标准与关键数值

  • 跟腱硬度中位数:职业组11.12 m/s vs 半职业组7.33 m/s,P < .001。
  • 比目鱼肌止点硬度中位数:职业组1.77 m/s vs 半职业组1.14 m/s,P < .001。
  • 股内侧肌硬度中位数:职业组1.63 m/s vs 半职业组0.87 m/s,P < .001。
  • 股四头肌腱硬度中位数:职业组3.31 m/s vs 半职业组2.61 m/s,P < .05。
  • 髌腱硬度中位数:职业组2.57 m/s vs 半职业组3.21 m/s,P = .25,两组无显著差异。

临床应用与阅片要点

  • 作者认为了解职业与半职业运动员间肌肉肌腱硬度差异对诊断肌腱病与损伤是必要的。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Shear wave elastography (SWE) allows assessment of muscle and tendon stiffness and can be used to diagnose soft tissue pathologies such as tendinopathies. In sports medicine, SWE may have the potential to uncover structural changes early on before they lead to functional impairment. To systematically analyze possible differences in tendon and muscle stiffness of the lower limb between professional (PG) and semiprofessional female athletes (SG) using SWE and to compile reference values for developing preventive medicine approaches for professional athletes.

METHODS: Standardized SWE of both lower limb tendons and muscles (Achilles tendon [AT], soleus muscle insertion [SM], patellar tendon [PT], quadriceps tendon [QT], vastus medialis muscle [VM]) in the longitudinal plane was performed with the tendons in relaxed position in 24 healthy professional female athletes (PG) in comparison with 24 healthy semiprofessional female athletes (SG).

RESULTS: Median tendon and muscle stiffness was significantly higher in professional athletes (AT:PG, 11.12 m/s vs SG, 7.33 m/s, P < .001; SM: 1.77 m/s vs 1.14 m/s, P < .001; VM: 1.63 m/s vs 0.87 m/s, P < .001; QT: 3.31 m/s vs 2.61 m/s, P < .05). There was no significant difference in patellar tendon stiffness between PG and SG (PT: 2.57 m/s vs 3.21, P = .25).

CONCLUSION: Professional female athletes have higher stiffness values than semiprofessional female athletes in lower limb muscles and tendons, except for the patellar tendon. Knowledge of such differences is necessary for diagnosing tendinopathy and injuries. Musculoskeletal SWE could offer great benefits in sports medicine as well as in rehabilitation and preventive medicine.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Romer, Czupajllo, Zessin, et al. Stiffness of Muscles and Tendons of the Lower Limb of Professional and Semiprofessional Athletes Using Shear Wave Elastography. J Ultrasound Med. 2022. PMID: 35900250. doi:10.1002/jum.16062

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。