文献速递泌尿生殖腹部MR

基于深度学习的并发计算机辅助检测系统用于前列腺多参数MRI:一项纳入经验丰富与经验较少放射科医师的性能研究

A concurrent, deep learning-based computer-aided detection system for prostate multiparametric MRI: a performance study involving experienced and less-experienced radiologists.
PubMed 文献 · Eur Radiol · 2022-07-28

回顾性多阅片者多病例研究纳入184例患者(最终分析172例),以靶向联合12针系统经直肠超声引导活检为参考标准,比较4名放射科医师(2名经验丰富、2名经验较少)在无和有深度学习计算机辅助诊断(DL-CAD)辅助下诊断前列腺癌的效能。DL-CAD辅助使经验较少医师的总体AUC从0.66升至0.80(ISUP GG≥1,p=0.001)和从0.68升至0.80(ISUP GG≥2,p=0.002),经验丰富医师AUC升高未达统计学显著;PI-RADS分类与Gleason评分相关性从0.45提高至0.57(p=0.03),中位阅片时间从157秒缩短至150秒(p=0.023)。

要点

  • DL-CAD辅助使经验较少医师AUC从0.66升至0.80(ISUP GG≥1,p=0.001)。
  • DL-CAD辅助使PI-RADS分类与Gleason评分相关性从0.45提高至0.57(p=0.03)。
  • DL-CAD辅助使中位阅片时间从157秒缩短至150秒(p=0.023)。

核心结论

  • DL-CAD辅助提高了平均检出效能,对经验较少医师获益最显著,使其达到与经验丰富医师相当的检出效能。

研究设计与样本

  • 回顾性、多阅片者多病例研究,纳入2018年1月至2019年8月连续184例患者,最终分析172例;参考标准为靶向联合12针系统经直肠超声引导活检;4名放射科医师(2名经验丰富、2名经验较少)每例分别在不使用(DL-CAD-)和使用DL-CAD(DL-CAD+)辅助下各评估一次。

诊断标准与关键数值

  • 经验较少医师总体AUC在DL-CAD辅助下从0.66升至0.80(p=0.001;截断值ISUP GG≥1),从0.68升至0.80(p=0.002;截断值ISUP GG≥2)。

临床应用与阅片要点

  • DL-CAD作为并发阅片辅助工具可帮助放射科医师区分前列腺MRI上的良性与癌性病变;经验较少医师在DL-CAD辅助下可能达到与经验丰富医师相当的检出效能;DL-CAD辅助提高了PI-RADS分类与肿瘤分级之间的相关性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the effect of a deep learning-based computer-aided diagnosis (DL-CAD) system on experienced and less-experienced radiologists in reading prostate mpMRI.

METHODS: In this retrospective, multi-reader multi-case study, a consecutive set of 184 patients examined between 01/2018 and 08/2019 were enrolled. Ground truth was combined targeted and 12-core systematic transrectal ultrasound-guided biopsy. Four radiologists, two experienced and two less-experienced, evaluated each case twice, once without (DL-CAD-) and once assisted by DL-CAD (DL-CAD+). ROC analysis, sensitivities, specificities, PPV and NPV were calculated to compare the diagnostic accuracy for the diagnosis of prostate cancer (PCa) between the two groups (DL-CAD- vs. DL-CAD+). Spearman's correlation coefficients were evaluated to assess the relationship between PI-RADS category and Gleason score (GS). Also, the median reading times were compared for the two reading groups.

RESULTS: In total, 172 patients were included in the final analysis. With DL-CAD assistance, the overall AUC of the less-experienced radiologists increased significantly from 0.66 to 0.80 (p = 0.001; cutoff ISUP GG ≥ 1) and from 0.68 to 0.80 (p = 0.002; cutoff ISUP GG ≥ 2). Experienced radiologists showed an AUC increase from 0.81 to 0.86 (p = 0.146; cutoff ISUP GG ≥ 1) and from 0.81 to 0.84 (p = 0.433; cutoff ISUP GG ≥ 2). Furthermore, the correlation between PI-RADS category and GS improved significantly in the DL-CAD + group (0.45 vs. 0.57; p = 0.03), while the median reading time was reduced from 157 to 150 s (p = 0.023).

CONCLUSIONS: DL-CAD assistance increased the mean detection performance, with the most significant benefit for the less-experienced radiologist; with the help of DL-CAD less-experienced radiologists reached performances comparable to that of experienced radiologists.

KEY POINTS: • DL-CAD used as a concurrent reading aid helps radiologists to distinguish between benign and cancerous lesions in prostate MRI. • With the help of DL-CAD, less-experienced radiologists may achieve detection performances comparable to that of experienced radiologists. • DL-CAD assistance increases the correlation between PI-RADS category and cancer grade.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Labus, Altmann, Huisman, et al. A concurrent, deep learning-based computer-aided detection system for prostate multiparametric MRI: a performance study involving experienced and less-experienced radiologists. Eur Radiol. 2022. PMID: 35900376. doi:10.1007/s00330-022-08978-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。