支架穹隆技术对颅内分叉部动脉瘤栓塞结局的影响
回顾性评估2012年11月至2018年10月用LEO Baby支架辅助栓塞的未破裂分叉部动脉瘤,比较支架穹隆技术(A组36个)与经典支架辅助栓塞(B组30个)的结局。A组动脉瘤更大、瘤颈更宽(P=.02和P=.04),平均随访27.30个月,两组并发症率、闭塞状态及早期和长期闭塞率均无显著差异,支架穹隆技术未预测最终影像随访的完全闭塞(Raymond-Roy I)。
要点
- 支架穹隆技术可用于栓塞更大、宽颈的分叉部动脉瘤。
- 与常规支架辅助栓塞相比,未观察到支架穹隆技术额外的血流导向效应。
- 支架穹隆技术未预测最终随访时Raymond-Roy I级完全闭塞。
核心结论
- 支架穹隆技术使更大、宽颈动脉瘤的栓塞成为可能,但与常规支架辅助栓塞相比未观察到额外的血流导向效应,且该技术未预测最终影像随访的完全闭塞(Raymond-Roy I)。
研究设计与样本
- 回顾性研究,纳入2012年11月至2018年10月用单一类型低剖面编织支架(LEO Baby)行支架辅助栓塞的未破裂分叉部动脉瘤,共61例患者(29名男性,47.5%;平均年龄55.95岁,SD 12.33)的66个动脉瘤,A组36个用支架穹隆技术,B组30个用经典支架辅助栓塞。
诊断标准与关键数值
- 完全闭塞定义为Raymond-Roy I级;A组动脉瘤大小和瘤颈宽度显著大于B组(P=.02和P=.04);平均随访27.30个月(SD 17.45),两组并发症率、闭塞状态及早期和长期闭塞率无显著差异;支架穹隆技术未预测最终影像随访的完全闭塞(Raymond-Roy I)。
临床应用与阅片要点
- 作者建议使用该技术时尽可能致密且安全地栓塞分叉部动脉瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Stent bulging technique has been introduced as a technique that improves the outcome of aneurysm coiling. Our aim was to evaluate the utility of this technique, which involves the intentional herniation of stents into the bifurcation aneurysms during coiling.
MATERIALS AND METHODS: Unruptured bifurcation aneurysms treated by stent-assisted coiling using a single type of low-profile braided (LEO Baby) stent between November 2012 and October 2018 were retrospectively evaluated. The clinical (age and sex) and morphologic characteristics (aneurysm size, neck size, proximal/distal diameters of the stented artery, incorporation of the origins of the side branches to the aneurysm neck, and bifurcation angle) and response to antiplatelet therapy were evaluated.
RESULTS: Sixty-one patients (29 men, 47.5%; mean age, 55.95 [SD, 12.33] years) with 66 aneurysms were included. There were 36 aneurysms in group A (treated with the stent bulging technique) and 30 aneurysms in group B (treated by classic stent-assisted coiling). There was no significant difference in the patient and aneurysm characteristics in the groups except for the larger size and wider neck of the aneurysms in group A (P = .02 and P = .04, respectively). At the mean follow-up of 27.30 (SD, 17.45) months, there was no significant difference in the complication rate, the occlusion status, and the early and long-term occlusion rates between the groups. The stent bulging technique did not predict total occlusion (Raymond-Roy I) at the final imaging follow-up.
CONCLUSIONS: The stent bulging technique enables the coiling of larger, wide-neck aneurysms; however, we did not observe an added flow-diversion effect with the stent bulging technique compared with conventional stent-assisted coiling. We, therefore, suggest that bifurcation aneurysms should be coiled as densely and as safely as possible using this technique.
引用
- Çay, Arat. Effect of the Shelving Technique on the Outcome of Embolization in Intracranial Bifurcation Aneurysms. AJNR Am J Neuroradiol. 2022. PMID: 35902123. doi:10.3174/ajnr.A7583
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。