T2暗带胎盘内条带最大长度可能有助于预测胎盘植入谱系孕妇的术中出血
回顾性纳入86例胎盘植入谱系(PAS)孕妇,术前MRI测量T2暗带胎盘内条带最大长度(MLTIB)并记录其他征象。MLTIB预测术中出血≥1000 ml的最佳阈值为28.95 mm(AUC 0.91,敏感度84%,特异度91%),预测≥2000 ml为35.65 mm(AUC 0.94,敏感度89%,特异度85%)。结论认为MLTIB与术中出血相关,大于28.95 mm是有效预测指标,35.65 mm及以上强烈提示大量出血可能。
要点
- 胎盘床异常血管化预测术中出血的相对风险比最高(RR=10.66),其次为T2暗带胎盘内条带(RR=8.02)。
- MLTIB预测术中出血≥1000 ml的最佳阈值为28.95 mm,AUC 0.91,敏感度84%,特异度91%。
- MLTIB预测大量术中出血≥2000 ml的最佳阈值为35.65 mm,AUC 0.94,敏感度89%,特异度85%。
核心结论
- MLTIB与PAS孕妇术中出血相关,大于28.95 mm是术中出血的有效预测指标,35.65 mm及以上强烈提示大量术中出血可能。
研究设计与样本
- 回顾性研究,2018年2月至2021年2月在浙江省台州医院分娩并术前行MRI检查的86例PAS孕妇。
关键影像表现/征象
- 记录T2暗带胎盘内条带、胎盘/子宫膨隆、胎盘后T2低信号线消失、子宫肌层变薄、膀胱壁中断、局灶性外生性肿块及胎盘床异常血管化。
- 测量T2暗带胎盘内条带最大长度(MLTIB)。
诊断标准与关键数值
- MLTIB预测术中出血≥1000 ml的最佳阈值为28.95 mm,AUC 0.91,敏感度84%,特异度91%。
- MLTIB预测大量术中出血≥2000 ml的最佳阈值为35.65 mm,AUC 0.94,敏感度89%,特异度85%。
- 胎盘床异常血管化预测术中出血的RR=10.66,T2暗带胎盘内条带存在RR=8.02。
临床应用与阅片要点
- 86例中32例术中出血≥1000 ml,其中18例≥2000 ml。
- 作者认为MLTIB大于28.95 mm是术中出血的有效预测指标,35.65 mm及以上强烈提示大量术中出血可能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the relationship between the maximum length of T2-dark intraplacental bands (MLTIB) and intraoperative haemorrhage in pregnant women with placenta accreta spectrum (PAS).
METHODS: Between February 2018 and February 2021, 86 pregnant women with PAS who delivered in Taizhou Hospital of Zhejiang Province and underwent preoperative magnetic resonance imaging (MRI) examination were retrospectively recruited. The presence of T2-dark intraplacental bands, placental/uterine bulge, loss of retroplacental T2-hypointense line, myometrial thinning, bladder wall interruption, focal exophytic mass, and abnormal vascularization of placental bed were recorded, and the MLTIB was measured. The relative risk ratios of the MRI findings and intraoperative bleeding were measured. Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the MLTIB to help predict intraoperative haemorrhage in pregnant women with PAS.
RESULTS: Of the 86 pregnant women, 32 had intraoperative blood loss ≥ 1000 ml; of these, 18 had intraoperative blood loss ≥ 2000 ml. Abnormal vascularization of placental bed was associated with the highest relative risk ratio for the detection of intraoperative haemorrhage (RR = 10.66), followed by the presence of T2-dark intraplacental bands (RR = 8.02). The optimal cut-off of the MLTIB for predicting intraoperative haemorrhage (≥ 1000 ml) in pregnant women with PAS was 28.95 mm, and the AUC was 0.91 (sensitivity: 84%; specificity: 91%). The optimal cut-off of the MLTIB for predicting massive intraoperative haemorrhage (≥ 2000 ml) was 35.65 mm, and the AUC was 0.94 (sensitivity: 89%; specificity: 85%).
CONCLUSION: MLTIB was related to intraoperative haemorrhage in pregnant women with PAS. An MLTIB greater than 28.95 mm is an effective predictor of intraoperative haemorrhage. An MLTIB of 35.65 mm or greater strongly suggests the possibility of massive intraoperative haemorrhage.
引用
- Wu, Zhou, Lin, et al. The maximum length of T2-dark intraplacental bands may help predict intraoperative haemorrhage in pregnant women with placenta accreta spectrum (PAS). Abdom Radiol (NY). 2022. PMID: 35896684. doi:10.1007/s00261-022-03619-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。