文献速递儿科影像头颈US

超声测定儿童甲状腺质量

Ultrasound determination of pediatric thyroid mass.
PubMed 文献 · Pediatr Radiol · 2022-07-26

该回顾性研究纳入86例18岁以下、超声与甲状腺切除术间隔小于6个月的患者,比较超声估算甲状腺质量与切除标本质量。所有已发表转换因子估算质量与标本质量均呈强正相关(r=0.95),平均差异从-0.34 g(转换因子=0.523)到1.69 g(转换因子=0.554),研究样本最佳简化因子为0.537。

要点

  • 超声线性测量结合已发表转换因子可较好估算儿童甲状腺质量,平均误差小于2 g。
  • 不同转换因子估算质量与标本质量均强相关(r=0.95),平均差异-0.34至1.69 g。
  • 本研究样本最佳简化转换因子为0.537。

核心结论

  • 所有已发表转换因子基于超声线性测量估算甲状腺质量均能给出良好估计,平均误差小于2 g。

研究设计与样本

  • 回顾性豁免研究,纳入2010年1月至2020年6月间86例小于18岁、甲状腺超声与甲状腺切除术间隔小于6个月的患者,收集超声甲状腺尺寸、切除术标本质量及组织病理诊断,采用已发表转换因子以密度1.05 g/cm3估算甲状腺体积并转换为质量,使用Pearson相关和Bland-Altman差异分析,线性回归计算最佳转换因子。

诊断标准与关键数值

  • 所有测试转换因子估算质量与标本质量均呈强正相关(r=0.95);超声估算质量与实测质量平均差异从-0.34 g(转换因子=0.523)到1.69 g(转换因子=0.554);研究样本最佳简化估算因子为0.537。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Radioiodine therapy for Graves disease can be achieved with dosing based on estimated thyroid gland mass. Thyroid mass can be estimated using linear ultrasound measurements, and conversion factors for volume and density. The choice of conversion factors could impact estimated thyroid mass and thus administered radioiodine dose.

OBJECTIVE: The objective of this study was to define the relationship between thyroid mass estimated by ultrasound and measured thyroid mass following thyroidectomy.

MATERIALS AND METHODS: This was a retrospective, exempt study that included patients < 18 years of age with < 6 months between thyroid ultrasound and thyroidectomy January 2010-June 2020. Thyroid dimensions by ultrasound, thyroid mass at thyroidectomy and histopathological diagnosis were collected. Published conversion factors were used to estimate thyroid volume with conversion to mass using a density of 1.05 g/cm3. Pearson correlations and Bland-Altman difference analyses were used to define the relationship between estimated mass and specimen weight. Linear regression was used to calculate an optimal conversion factor for estimating thyroid mass.

RESULTS: We included 86 patients, 67 female (78%), with a mean age of 14.5 ± 3.15 years. Mass estimated using all tested conversion factors had similar strong, positive correlation with specimen weight (r = 0.95). The mean difference between thyroid mass estimated by ultrasound and measured mass ranged from - 0.34 g (conversion factor = 0.523) to 1.69 g (conversion factor = 0.554). The optimal simplified factor for estimation of thyroid mass for the study sample was 0.537.

CONCLUSION: All published conversion factors for estimating thyroid mass based on linear ultrasound measurements produce good estimates of thyroid mass. Errors in estimated mass are less than 2 g on average.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Crothers, Chuang, Sharp, et al. Ultrasound determination of pediatric thyroid mass. Pediatr Radiol. 2022. PMID: 35881167. doi:10.1007/s00247-022-05450-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。