无造影剂超快超声微血管成像中的自适应稳健血管定量方法
针对超快超声微血管成像(UMI)中空间依赖噪声和非相干杂波伪影降低血管定量可靠性的问题,作者提出改进的UMI技术及自适应血管分割流程,并在CIRS体模、多普勒血流体模及炎症性肠、肾、肝组织上验证其可行性,结果显示该方法可实现自动、自适应且稳健的血管识别,且不受放射科医师/操作者主观性影响。
要点
- 提出结合亚孔径互相关与归一化互相关的改进UMI技术,用于均衡空间依赖噪声并抑制非相干杂波伪影。
- 采用方形算子与非局部均值滤波进一步分离血流信号与残余背景噪声。
- 基于血流信号与背景噪声空间模式差异开发自动自适应血管分割方法,在体模及炎症性肠、肾、肝组织上验证可行。
核心结论
- 所提流程可实现自动、自适应且稳健的血管识别与血管特征定量,避免放射科医师/操作者主观性。
研究设计与样本
- 方法学研究,在CIRS体模、多普勒血流体模及炎症性肠、肾、肝组织上验证可行性,具体样本量原文未报告。
临床应用与阅片要点
- 原文结论提示该流程可实现自动、自适应且稳健的血管识别,并避免放射科医师/操作者主观性。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The morphological features of vasculature in diseased tissue differ significantly from those in normal tissue. Therefore, vasculature quantification is crucial for disease diagnosis and staging. Ultrasound microvessel imaging (UMI) with ultrafast ultrasound acquisitions has been determined to have potential in clinical applications given its superior sensitivity in blood flow detection. However, the presence of spatial-dependent noise caused by a low imaging signal-to-noise ratio and incoherent clutter artifacts caused by moving hyperechoic scatterers degrades the performance of UMI and the reliability of vascular quantification. To tackle these issues, we proposed an improved UMI technique along with an adaptive vessel segmentation workflow for robust vessel identification and vascular feature quantification. A previously proposed sub-aperture cross-correlation technique and a normalized cross-correlation technique were applied to equalize the spatially dependent noise level and suppress the incoherent clutter artifact. A square operator and non-local means filter were then used to better separate the blood flow signal from residual background noise. On the de-noised ultrasound microvessel image, an automatic and adaptive vessel segmentation method was developed based on the different spatial patterns of blood flow signal and background noise. The proposed workflow was applied to a CIRS phantom, to a Doppler flow phantom and to an inflammatory bowel, kidney and liver, to validate its feasibility. Results revealed that automatic adaptive, and robust vessel identification performance can be achieved using the proposed method without the subjectivity caused by radiologists/operators.
引用
- Tang, Huang, Gong, et al. Adaptive and Robust Vessel Quantification in Contrast-Free Ultrafast Ultrasound Microvessel Imaging. Ultrasound Med Biol. 2022. PMID: 35882573. doi:10.1016/j.ultrasmedbio.2022.05.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。