儿童和青少年肝脏化学位移编码PDFF采样策略的回顾性比较
该回顾性研究纳入50例儿童和青少年的临床MRI PDFF采集,以每个Couinaud段2个ROI共18个ROI为参考标准,比较四种文献报道的ROI采样策略。所有采样策略与参考标准强相关(ρ=0.995-0.998)且一致性极好(ICC 0.995-0.998),平均差异不显著;仅采样右叶的策略可能高估肝脏PDFF。
要点
- 儿童肝脏PDFF使用大ROI的采样策略与每段采样参考标准强相关且一致性极好。
- 右叶PDFF显著高于左叶(24.0±13.7% vs 22.0±13.1%,p=0.001)。
- 仅采样右叶的策略可能高估肝脏PDFF。
核心结论
- 儿童肝脏PDFF使用大ROI的采样策略与每Couinaud段采样的参考标准强相关、一致性极好且平均差异不显著;仅采样右叶的策略可能高估肝脏PDFF。
研究设计与样本
- 回顾性、经内部审查委员会批准的研究,纳入50例儿童和青少年的临床MRI PDFF采集,以每段2个ROI共18个ROI的采样范式为参考标准,复现四种文献报道的ROI采样范式测量平均肝脏PDFF,采用Spearman相关、组内相关系数(ICC)和Bland-Altman分析量化一致性。
诊断标准与关键数值
- 参考标准为18-ROI范式(每个Couinaud段2个ROI)测量的平均肝脏PDFF。
- 各单个Couinaud段PDFF与参考标准高度相关(ρ=0.977至0.993,p<0.0001)。
- 所有采样范式(包括大自由手绘ROI策略)与参考标准强相关(ρ=0.995至0.998,p<0.0001),一致性极好(ICC范围0.995至0.998)。
- 基于18-ROI范式,右叶平均PDFF显著高于左叶(右叶24.0±13.7% vs 左叶22.0±13.1%,p=0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Multiple region-of-interest (ROI) sampling strategies have been described for liver fat quantification by MRI PDFF. While adult studies have shown that sampling strategies including as few as four ROIs provide a reasonable tradeoff between laboriousness and quantitative performance, there is a paucity of similar data for pediatric patients.
PURPOSE: To assess agreement between different ROI sampling strategies for liver MRI PDFF analysis in children and adolescents.
MATERIALS AND METHODS: This retrospective, internal review board-approved study included clinical MRI PDFF acquisitions for 50 children and adolescents. Four different ROI sampling paradigms reported in the literature were reproduced to measure mean liver PDFF. An 18-ROI (2 in each Couinaud segment) paradigm was considered the reference standard. Spearman correlation, intraclass correlation coefficients (ICCs), and Bland-Altman analyses were used to quantify agreement.
RESULTS: Mean age for the 50 participants was 14 ± 2.5 years (range 8-17 years). Based on the 18-ROI paradigm, mean PDFF was significantly higher for the right lobe (24.0 ± 13.7% right, 22.0 ± 13.1% left; p = 0.001). PDFF values for each individual Couinaud segment were highly correlated with the reference standard (ρ = 0.977 to 0.993, p < 0.0001). PDFF values derived from all sampling paradigms, including strategies using large free-hand ROIs, were strongly correlated with the reference standard (ρ = 0.995 to 0.998, p < 0.0001) with excellent agreement (ICC range 0.995 to 0.998).
CONCLUSION: Liver PDFF sampling paradigms using large ROIs showed strong correlation, excellent agreement, and nonsignificant mean differences from a reference standard paradigm sampling every Couinaud segment in children. Paradigms that exclusively sample the right lobe may overestimate liver PDFF.
引用
- de Padua V Alves, Dillman, Trout, et al. Retrospective comparison of liver chemical shift-encoded PDFF sampling strategies in children and adolescents. Abdom Radiol (NY). 2022. PMID: 35864263. doi:10.1007/s00261-022-03615-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。