脑实质血管系统在脑脊液示踪剂清除中的作用
本研究在大鼠枕大池注入不同脑脊液示踪剂后,用SPIO-SWI和QSM在7 T MRI上定量观察脑实质静脉、动脉及其血管旁间隙的信号变化,发现脑实质静脉系统参与脑脊液示踪剂清除,且静脉内示踪剂多于动脉。
要点
- 脑实质静脉系统直接参与脑脊液示踪剂清除。
- 不同大小的MRI示踪剂均可进入脑实质静脉系统。
- 脑实质动脉内示踪剂进入量可忽略。
核心结论
- MRI示踪剂可进入脑实质血管系统,且脑实质静脉内示踪剂多于动脉,提示脑实质血管系统直接参与脑废物清除。
研究设计与样本
- 动物实验,26只大鼠,枕大池注入不同脑脊液示踪剂(FeREX、Ferumoxytol、Fe-Dextran),用7 T MRI的SPIO-SWI和QSM定量研究脑实质静脉、动脉及其血管旁间隙的信号变化。
关键影像表现/征象
- 脑实质静脉系统参与脑脊液示踪剂清除,在注射75 μg铁时更明显。
- 脑实质静脉磁化率相对均值(±SE)在示踪剂注入后15分钟较基线增加13.5(±1.0)%(p < 0.01),45分钟增加33.6(±6.7)%(p = 0.01)。
- 脑实质动脉在示踪剂注入后15分钟较基线变化1.3(±2.6)%(p = 0.6),45分钟变化12(±19)%(p = 0.5),进入量可忽略。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The current understanding of cerebral waste clearance (CWC) involves cerebrospinal fluid (CSF) participation but lacks convincing evidence for the direct participation of the parenchymal vascular system. The objective of this study was to evaluate the role of the parenchymal vascular system in CSF tracer clearance in rats.
METHODS: We used superparamagnetic iron oxide-enhanced susceptibility-weighted imaging (SPIO-SWI) and quantitative susceptibility mapping (QSM) methods to simultaneously study 7 T MRI signal changes in parenchymal veins, arteries, and their corresponding para-vascular spaces in 26 rats, following intra-cisterna magna (ICM) infusion of different CSF tracers (FeREX, Ferumoxytol, Fe-Dextran) to determine the amount of tracer in the artery and vein quantitatively.
RESULTS: We observed that the parenchymal venous system participated in CSF tracer clearance following ICM infusion of different MRI tracers with different concentrations of iron. Parenchymal venous participation was more obvious when 75 μg iron was injected. In the parenchymal veins, the relative mean (± SE) value of the susceptibility increased by 13.5 (± 1.0)% at 15 min post-tracer infusion (p < 0.01), and 33.6 (± 6.7)% at 45 min post-tracer infusion (p = 0.01), compared to baseline. In contrast to the parenchymal veins, a negligible amount of CSF tracer entered the parenchymal arteries: 1.3 (± 2.6)% at 15 min post-tracer infusion (p = 0.6), and 12 (± 19)% at 45 min post-tracer infusion (p = 0.5), compared to baseline.
CONCLUSIONS: MRI tracers can enter the parenchymal vascular system and more MRI tracers were observed in the cerebral venous than arterial vessels, suggesting the direct participation of parenchymal vascular system in CWC.
KEY POINTS: • MRI results revealed that the parenchymal venous system directly participates in cerebrospinal fluid tracer clearance following ICM infusion of MRI tracer. • Different sizes of MRI tracers can enter the parenchymal venous system.
引用
- Hu, Shen, Fahmy, et al. The role of the parenchymal vascular system in cerebrospinal fluid tracer clearance. Eur Radiol. 2022. PMID: 35852578. doi:10.1007/s00330-022-09022-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。