不同三维剪切波弹性成像切面在甲状腺结节诊断中的价值
本研究纳入188例患者共216个甲状腺结节,均行常规超声、二维剪切波弹性成像(SWE)与三维SWE检查,以手术病理为金标准。结果显示三维SWE各切面杨氏模量值在恶性结节中均显著高于良性结节,三维SWE横切面与矢状面Emax的AUC显著高于二维SWE横切面,三维SWE联合ACR TI-RADS较单用ACR TI-RADS显著提高特异度与诊断准确率。
要点
- 恶性甲状腺结节在二维及三维SWE各切面的杨氏模量值均显著高于良性结节(p < 0.001)。
- 三维SWE横切面及矢状面Emax的AUC(0.831、0.844)显著高于二维SWE横切面(0.768)。
- 三维S-Emax联合ACR TI-RADS的AUC为0.859,特异度由54.84%升至85.71%,准确率由74.54%升至85.19%。
核心结论
- 三维SWE联合ACR TI-RADS可显著提高ACR TI-RADS对甲状腺结节的诊断能力,且显著优于二维SWE联合ACR TI-RADS。
研究设计与样本
- 本研究共纳入188例患者216个结节,均行常规超声、二维SWE及三维SWE检查,全部患者接受手术切除,以病理结果为金标准。
关键影像表现/征象
- 甲状腺恶性结节在二维SWE与三维SWE不同切面的杨氏模量值(Emin、Emean、Emax、Esd)均显著高于良性结节(p < 0.001)。
- 三维SWE横切面及矢状面的Emax AUC分别为0.831和0.844,二维SWE横切面Emax AUC为0.768,二维SWE横切面显著低于三维SWE横切面及矢状面(p < 0.05)。
诊断标准与关键数值
- 二维SWE横切面Emax的AUC为0.768,三维SWE横切面Emax的AUC为0.831,三维SWE矢状面Emax的AUC为0.844。
- 三维S-Emax联合ACR TI-RADS的AUC为0.859,特异度85.71%,诊断准确率85.19%。
- 单用ACR TI-RADS的特异度为54.84%,诊断准确率为74.54%。
临床应用与阅片要点
- 三维SWE横切面与矢状面Emax对甲状腺良恶性结节的鉴别效能均优于二维SWE横切面。
- 三维S-Emax联合ACR TI-RADS可在维持较高敏感度的同时将特异度由54.84%提高至85.71%,诊断准确率由74.54%提高至85.19%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of the study was to explore the value of 3-D shear wave elastography (SWE) in differentiating malignant from benign thyroid nodules. A total of 188 patients with 216 nodules who underwent conventional ultrasound, 2-D SWE and 3-D SWE were included in this study. All patients underwent surgical excision, and the pathological results were the gold standard. Receiver operating characteristic (ROC) curves of the American College of Radiology's Thyroid Imaging Reporting and Data System (ACR TI-RADS), 2-D SWE and 3-D SWE were plotted, and the areas under the curves (AUCs) were compared using a Z-test. There were 62 benign thyroid nodules and 154 malignant thyroid nodules in this study. Young's modulus (Emin, Emean, Emax, Esd) values of thyroid malignant nodules in different sections of 2-D SWE and 3-D SWE were significantly higher than those of thyroid benign nodules (p < 0.001). The AUC of Emax in 2-D SWE transverse sections was significantly lower than that in 3-D SWE transverse sections and 3-D SWE sagittal sections (0.768 vs. 0.831 and 0.844, p < 0.05). The AUC of 3-D S-Emax combined with ACR TI-RADS was 0.859; the specificity increased from 54.84% to 85.71%, and the diagnostic accuracy increased from 74.54% to 85.19%, compared with ACR TI-RADS. The difference was statistically significant (p < 0.05). Three-dimensional SWE combined with ACR TI-RADS for the diagnosis of thyroid nodules significantly improved the diagnostic ability of ACR TI-RADS, and was significantly better than 2-D SWE combined with ACR TI-RADS.
引用
- Hu, Lu, Wang, et al. Diagnostic Value of Different 3-D Shear Wave Elastography Sections in the Diagnosis of Thyroid Nodules. Ultrasound Med Biol. 2022. PMID: 35853762. doi:10.1016/j.ultrasmedbio.2022.05.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。