文献速递乳腺技术与安全US

基于超声影像组学列线图预测浸润性导管乳腺癌Ki-67表达

Prediction of Ki-67 of Invasive Ductal Breast Cancer Based on Ultrasound Radiomics Nomogram.
PubMed 文献 · J Ultrasound Med · 2022-07-19

研究回顾性纳入2016年12月至2018年12月515例接受二维超声和Ki-67检查的浸润性导管乳腺癌患者,按7:3随机分为训练组360例和测试组155例,提取超声影像组学特征并结合临床独立预测因子构建列线图。测试组列线图预测Ki-67的AUC为0.770(95%CI 0.690-0.860),在两个队列中均优于临床模型和影像组学模型(DeLong检验P<.05),决策曲线分析证明模型具有临床实用性。

要点

  • 基于二维超声影像组学列线图可在术前预测乳腺浸润性导管癌Ki-67表达。
  • 测试组列线图AUC为0.770(95%CI 0.690-0.860)。
  • 列线图在两个队列中均优于临床模型和影像组学模型(P<.05)。

核心结论

  • 基于二维超声图像的列线图为预测乳腺癌Ki-67提供了一种方法。

研究设计与样本

  • 回顾性研究,纳入2016年12月至2018年12月515例接受二维超声和Ki-67检查的浸润性导管乳腺癌患者,按7:3随机分为训练组(n=360)和测试组(n=155)。

诊断标准与关键数值

  • 测试组列线图预测Ki-67的AUC为0.770(95%CI 0.690-0.860);在两个队列中列线图均优于临床模型和影像组学模型(DeLong检验P<.05)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The objective of this research was to develop and validate an ultrasound-based radiomics nomogram for the pre-operative assessment of Ki-67 in breast cancer (BC).

MATERIALS AND METHODS: From December 2016 to December 2018, 515 patients with invasive ductal breast cancer who received two-dimensional (2D) ultrasound and Ki-67 examination were studied and analyzed retrospectively. The dataset was distributed at random into a training cohort (n = 360) and a test cohort (n = 155) in the ratio of 7:3. Each tumor region of interest was defined based on 2D ultrasound images and radiomics features were extracted. ANOVA, maximum correlation minimum redundancy (mRMR) algorithm, and minimum absolute shrinkage and selection operator (LASSO) were performed to pick features, and independent clinical predictors were integrated with radscore to construct the nomogram for predicting Ki-67 index by univariate and multivariate logistic regression analysis. The performance and utility of the models were evaluated by plotting receiver operating characteristic (ROC) curves, decision curve analysis (DCA), and calibration curves.

RESULTS: In the testing cohort, the area under the receiver characteristic curve (AUC) of the nomogram was 0.770 (95% confidence interval, 0.690-0.860). In both cohorts, the nomogram outperformed both the clinical model and the radiomics model (P < .05 according to the DeLong test). The analysis of DCA proved that the model has clinical utility.

CONCLUSIONS: The nomogram based on 2D ultrasound images offered an approach for predicting Ki-67 in BC.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhu, Dou, Qin, et al. Prediction of Ki-67 of Invasive Ductal Breast Cancer Based on Ultrasound Radiomics Nomogram. J Ultrasound Med. 2022. PMID: 35851691. doi:10.1002/jum.16061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。