冠状动脉钙化面积与密度不一致可预测长期动脉粥样硬化性心血管疾病风险
研究纳入CAC联盟10373例CAC>0的一级预防参与者,按钙化面积与平均钙化密度中位数分为4组,中位随访11.7年,校正传统危险因素和Agatston评分后,低面积/高密度组较CAC评分相近的低面积/低密度组ASCVD死亡风险降低71%(HR 0.29,95%CI 0.09-0.95),提示高钙化密度可能是病灶易损性的影像学生物标志。
要点
- CAC>0者中钙化面积/密度不一致占19%,其中低面积/高密度9%、高面积/低密度10%。
- 同等CAC评分下,低面积/高密度组较低面积/低密度组ASCVD死亡风险降低71%(HR 0.29,95%CI 0.09-0.95)。
- 高密度不一致与女性(OR 1.48)和较低BMI(每高5 kg/m² OR 0.81)相关,低密度不一致与糖尿病(OR 2.23)最强相关。
核心结论
- 对于给定CAC评分,相对斑块面积的高钙化密度与较低长期ASCVD风险相关,可能作为病灶易损性的生物学韧性影像标志;需进一步研究以确定钙化面积/密度不一致的稳健定义用于常规临床风险预测。
研究设计与样本
- CAC联盟一级预防参与者10373例,CAC>0,按钙化面积和平均钙化密度中位数分为4个互斥的一致/不一致组,Cox比例风险回归评估ASCVD死亡,中位随访11.7年,校正传统危险因素和Agatston CAC评分。
诊断标准与关键数值
- 以钙化面积和平均钙化密度各自中位值为界分为4组:低面积/低密度、低面积/高密度、高面积/低密度、高面积/高密度。
- 钙化面积/密度不一致总患病率19%,其中低面积/高密度9%、高面积/低密度10%。
- 低面积/高密度组较低面积/低密度组ASCVD死亡风险降低71%(HR 0.29,95%CI 0.09-0.95)。
- 女性与高密度不一致相关(OR 1.48,95%CI 1.27-1.74)。
- BMI每高5 kg/m²与高密度不一致相关(OR 0.81,95%CI 0.76-0.87),糖尿病与低密度不一致最强相关(OR 2.23,95%CI 1.85-3.19)。
临床应用与阅片要点
- 阅片报告CAC时除Agatston评分外,可关注钙化面积与平均钙化密度是否不一致,以辅助风险分层。
- 同等CAC评分下,低面积/高密度模式提示较低长期ASCVD死亡风险,高面积/低密度模式风险较高。
局限性
- 需要进一步研究以确定钙化面积/密度不一致的稳健定义,用于常规临床风险预测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Coronary artery calcium (CAC) is commonly quantified as the product of 2 generally correlated measures: plaque area and calcium density.
OBJECTIVES: The authors sought to determine whether discordance between calcium area and density has long-term prognostic importance in atherosclerotic cardiovascular disease (ASCVD) risk.
METHODS: The authors studied 10,373 primary prevention participants from the CAC Consortium with CAC >0. Based on their median values, calcium area and mean calcium density were divided into 4 mutually exclusive concordant/discordant groups. Cox proportional hazards regression assessed the association of calcium area/density groups with ASCVD mortality over a median of 11.7 years, adjusting for traditional risk factors and the Agatston CAC score.
RESULTS: The mean age was 56.7 years, and 24% were female. The prevalence of plaque discordance was 19% (9% low calcium area/high calcium density, 10% high calcium area/low calcium density). Female sex (odds ratio [OR]: 1.48 [95% CI: 1.27-1.74]) and body mass index (OR: 0.81 [95% CI: 0.76-0.87], per 5 kg/m2 higher) were significantly associated with high calcium density discordance, whereas diabetes (OR: 2.23 [95% CI: 1.85-3.19]) was most strongly associated with discordantly low calcium density. Compared to those with low calcium area/low calcium density, individuals with low calcium area/high calcium density had a 71% lower risk of ASCVD death (HR: 0.29 [95% CI: 0.09-0.95]).
CONCLUSIONS: For a given CAC score, high calcium density relative to plaque area confers lower long-term ASCVD risk, likely serving as an imaging marker of biological resilience for lesion vulnerability. Additional research is needed to define a robust definition of calcium area/density discordance for routine clinical risk prediction.
引用
- Razavi, van Assen, De Cecco, et al. Discordance Between Coronary Artery Calcium Area and Density Predicts Long-Term Atherosclerotic Cardiovascular Disease Risk. JACC Cardiovasc Imaging. 2022. PMID: 35850937. doi:10.1016/j.jcmg.2022.06.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。