基于肌骨超声影像组学诊断滑雪者跟腱病的模型开发与验证
研究纳入88只临床诊断为单侧慢性跟腱病的滑雪者足和51只健康足,按入组时间分为训练集89只和测试集50只,从超声感兴趣区的红、绿、蓝通道及灰度图中提取833个影像组学特征,比较三种特征选择与三种机器学习算法构成的九种策略,绿通道联合随机森林选择与支持向量机建模表现最佳,训练集AUC 0.98、测试集AUC 0.99,敏感度0.90、特异度1。
要点
- 绿通道影像组学模型诊断跟腱病测试集AUC 0.99、敏感度0.90、特异度1。
- 所有入选影像组学特征均与跟腱病显著相关(P < .05)。
- 该模型可带来足够的临床净获益,可作为智能辅助诊断工具。
核心结论
- 基于超声图像的影像组学诊断性能高,可作为跟腱病诊断的智能辅助工具。
研究设计与样本
- 研究纳入88只临床诊断为单侧慢性跟腱病的滑雪者足和51只健康足,按入组时间顺序分为训练集89只和测试集50只,手动分割感兴趣区后从红、绿、蓝通道及灰度图分别提取833个影像组学特征,采用三种特征选择与三种机器学习建模算法比较九种影像组学分析策略,以AUC、一致性分析和决策分析评估诊断性能。
诊断标准与关键数值
- 绿通道影像组学模型采用随机森林特征选择与支持向量机建模,训练集AUC 0.98、测试集AUC 0.99、敏感度0.90、特异度1;所有入选影像组学特征均与跟腱病显著相关(P < .05)。
临床应用与阅片要点
- 作者认为该超声影像组学模型可作为跟腱病诊断的智能辅助工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Our study aimed to develop and validate an efficient ultrasound image-based radiomic model for determining the Achilles tendinopathy in skiers.
METHODS: A total of 88 feet of skiers clinically diagnosed with unilateral chronic Achilles tendinopathy and 51 healthy feet were included in our study. According to the time order of enrollment, the data were divided into a training set (n = 89) and a test set (n = 50). The regions of interest (ROIs) were segmented manually, and 833 radiomic features were extracted from red, green, blue color channels and grayscale of ROIs using Pyradiomics, respectively. Three feature selection and three machine learning modeling algorithms were implemented respectively, for determining the optimal radiomics pipeline. Finally, the area under the receiver operating characteristic curve (AUC), consistency analysis, and decision analysis were used to evaluate the diagnostic performance.
RESULTS: By comparing nine radiomics analysis strategies of three color channels and grayscale, the radiomic model under the green channel obtained the best diagnostic performance, using the Random Forest selection and Support Vector Machine modeling, which was selected as the final machine learning model. All the selected radiomic features were significantly associated with the Achilles tendinopathy (P < .05). The radiomic model had a training AUC of 0.98, a test AUC of 0.99, a sensitivity of 0.90, and a specificity of 1, which could bring sufficient clinical net benefits.
CONCLUSIONS: Ultrasound image-based radiomics achieved high diagnostic performance, which could be used as an intelligent auxiliary tool for the diagnosis of Achilles tendinopathy.
引用
- Wang, Wen, Yin, et al. Musculoskeletal Ultrasound Image-Based Radiomics for the Diagnosis of Achilles Tendinopathy in Skiers. J Ultrasound Med. 2022. PMID: 35841273. doi:10.1002/jum.16059
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。