文献速递乳腺乳腺X线

基于深度学习的超分辨率模型对乳腺X线摄影中微钙化的视觉与定量评估

Visual and quantitative evaluation of microcalcifications in mammograms with deep learning-based super-resolution.
PubMed 文献 · Eur J Radiol · 2022-07-06

研究连续收集2015年1月至2017年3月接受乳腺癌筛查的5080例患者乳腺X线摄影,其中93例(136侧乳腺,平均年龄50±7岁)存在微钙化。应用快速超分辨率卷积神经网络模型处理图像,由4名乳腺放射科医生以5分制视觉评估微钙化的检出、诊断质量、对比度、锐度和噪声,并用基于感知的图像质量评估器(PIQE)定量评估。结果显示超分辨率图像在微钙化检出、诊断质量、对比度和锐度上均优于原始图像(Wilcoxon符号秩检验p<.001),但3名放射科医生对噪声评分显著更低(p<.001);PIQE评分超分辨率图像优于原始图像(配对t检验p<.001)。

要点

  • 超分辨率模型可提升乳腺X线摄影中微钙化的检出、诊断质量、对比度和锐度。
  • 超分辨率图像的噪声评分显著低于原始图像(p<.001),阅片时需关注噪声变化。
  • PIQE定量评估同样显示超分辨率图像质量优于原始图像(p<.001)。

核心结论

  • 基于深度学习的超分辨率模型可改善乳腺X线摄影中微钙化的可见性,有助于微钙化的检出和诊断。

研究设计与样本

  • 研究为回顾性图像处理评估,连续收集2015年1月至2017年3月接受乳腺癌筛查的5080例患者乳腺X线摄影,其中93例(136侧乳腺,平均年龄50±7岁)存在微钙化;应用快速超分辨率卷积神经网络模型处理图像,由4名乳腺放射科医生进行5分制视觉评估,并以PIQE进行定量评估。

关键影像表现/征象

  • 所有放射科医生均认为超分辨率图像在微钙化检出、诊断质量、对比度和锐度方面优于原始图像(Wilcoxon符号秩检验p<.001)。
  • 3名放射科医生对超分辨率图像的噪声评分显著低于原始图像(p<.001)。
  • PIQE定量评估显示超分辨率图像评分优于原始图像(配对t检验p<.001)。

诊断标准与关键数值

  • 视觉评估采用5分制:1分为强烈偏好原始图像,5分为强烈偏好超分辨率图像,分别针对微钙化的检出、诊断质量、对比度、锐度和噪声进行评分。
  • 定量评估采用基于感知的图像质量评估器(PIQE)。

临床应用与阅片要点

  • 超分辨率处理后的乳腺X线图像可能有助于微钙化的检出和诊断,阅片时可参考其对比度和锐度改善。
  • 超分辨率图像的噪声评分较低,阅片时需注意噪声变化对图像判读的潜在影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate visually and quantitatively the performance of a deep-learning-based super-resolution (SR) model for microcalcifications in digital mammography.

METHOD: Mammograms were consecutively collected from 5080 patients who underwent breast cancer screening from January 2015 to March 2017. Of these, 93 patients (136 breasts, mean age, 50 ± 7 years) had microcalcifications in their breasts on mammograms. We applied an artificial intelligence model known as a fast SR convolutional neural network to the mammograms. SR and original mammograms were visually evaluated by four breast radiologists using a 5-point scale (1: original mammograms are strongly preferred, 5: SR mammograms are strongly preferred) for the detection, diagnostic quality, contrast, sharpness, and noise of microcalcifications. Mammograms were quantitatively evaluated using a perception-based image-quality evaluator (PIQE).

RESULTS: All radiologists rated the SR mammograms better than the original ones in terms of detection, diagnostic quality, contrast, and sharpness of microcalcifications. These ratings were significantly different according to the Wilcoxon signed-rank test (p <.001), while the noise score of the three radiologists was significantly lower (p <.001). According to PIQE, SR mammograms were rated better than the original mammograms, showing a significant difference by paired t-test (p <.001).

CONCLUSION: An SR model based on deep learning can improve the visibility of microcalcifications in mammography and help detect and diagnose them in mammograms.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Honjo, Ueda, Katayama, et al. Visual and quantitative evaluation of microcalcifications in mammograms with deep learning-based super-resolution. Eur J Radiol. 2022. PMID: 35834858. doi:10.1016/j.ejrad.2022.110433

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。