婴儿配方奶粉与医用对比剂短缺有何共同点:碘对比剂短缺管理的见解与建议

What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage
RSS 订阅 · 指南共识 · 对比剂与辐射安全 · 2022-07-14

该文借婴儿配方奶粉与碘对比剂短缺,揭示供应链脆弱性;作者描述某大型学术安全网县卫生系统通过优化CT对比剂使用和改变转诊医生开单模式来节约碘对比剂,并关注低kV与双能CT等心胸影像节约机会。

要点

  • 低kV与双能CT技术可用于心胸影像中节约碘对比剂。
  • 优化CT对比剂使用和改变转诊医生开单模式是节约碘对比剂的举措。
  • 单一供应商模式高效且经济,但其在关键医疗服务中的应用须被质疑。

核心结论

  • 婴儿配方奶粉与碘对比剂短缺暴露供应链关键脆弱性,促使卫生系统更审慎使用产品并采用此前已被推荐且被认为合理的行为。

研究设计与样本

  • 本文为经验描述文章,作者描述某大型学术安全网县卫生系统在碘对比剂短缺期间为节约碘对比剂所做的努力。

临床应用与阅片要点

  • 作者描述其所在大型学术安全网县卫生系统通过优化CT科室对比剂使用和改变转诊医生开单模式来节约碘对比剂,并特别关注心胸影像中低kV与双能CT技术的节约机会。

局限性

  • 原文未报告局限性
英文原文(摘要)· 点击展开

Radiol Cardiothorac Imaging. 2022 May 25;4(3):e220101. doi: 10.1148/ryct.220101. eCollection 2022 Jun. ABSTRACT The impact of supply chain and supply chain logistics, including personnel directly and indirectly related to the movement of supplies, has come to light in a variety of industries since the global COVID-19 pandemic. Acutely, the experience with baby formula and iodinated contrast material exposes key vulnerabilities to supply chains. The rather sudden diminished availability of iodinated contrast material has forced health care systems to engage in more judicious use of product through catalyzing the adoption of behaviors that had been recommended and deemed reasonable prior to the shortage. The authors describe efforts at a large, academic safety net county health system to conserve iodinated contrast media by optimizing contrast media use in the CT department and changing ordering patterns of referring providers. Special attention is given to opportunities to conserve contrast material in cardiothoracic imaging, including low kV and dual-energy CT techniques. A values-based leadership philosophy and collaboration with key stakeholders facilitate effective response to the critical shortage and rapid deployment of iodinated contrast media conservation strategies. Last, while the single-supplier model is efficient and cost-effective, its application to critically necessary services such as health care must be questioned considering disruptions related to the COVID-19 pandemic. Keywords: CT, Intravenous Contrast Agents, CT-Spectral Imaging (Dual Energy) ©RSNA, 2022. PMID: 35833167 | PMC: PMC9274312 | DOI: 10.1148/ryct.220101

来源:指南共识 · 对比剂与辐射安全,查看原文。版权归原作者所有。

引用

  1. 指南共识 · 对比剂与辐射安全:What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage