文献速递乳腺技术与安全US

腋窝淋巴结定量超声图像分析鉴别恶性肿瘤与COVID-19疫苗接种所致反应性良性改变

Quantitative ultrasound image analysis of axillary lymph nodes to differentiate malignancy from reactive benign changes due to COVID-19 vaccination.
PubMed 文献 · Eur J Radiol · 2022-07-07

本回顾性研究以超声引导下活检为参考标准,用新收集图像重新训练既往人工智能模型,并在含COVID-19疫苗接种后反应性良性淋巴结的图像上测试。模型在最优截断点的准确率为92.7%,敏感度77.8%,特异度100%;放射科医生视觉判读的准确率为69.7%,敏感度41.7%,特异度83.6%。作者认为该技术有潜力无创鉴别恶性淋巴结与疫苗接种后反应性良性淋巴结,但尚需更大规模多中心研究确认和验证。

要点

  • 模型鉴别恶性与疫苗反应性良性淋巴结的准确率92.7%、敏感度77.8%、特异度100%。
  • 放射科医生视觉判读的准确率69.7%、敏感度41.7%、特异度83.6%。
  • 作者认为该技术有潜力无创判断可疑反应性淋巴结的性质,但尚需更大规模多中心研究确认。

核心结论

  • 所提出的定量图像分析与机器学习技术有潜力鉴别恶性淋巴结与COVID-19疫苗接种所致反应性改变的良性淋巴结。
  • 作者认为这些技术可能有助于无创诊断可疑反应性淋巴结患者的淋巴结状态,但尚需更大规模多中心研究确认和验证结果。

研究设计与样本

  • 经机构审查委员会批准的回顾性研究,对既往发表的人工智能模型用新收集图像重新训练,并在含COVID-19疫苗接种后反应性良性淋巴结的图像上测试性能。
  • 共纳入154例患者的180幅新图像:71幅图像(10例病例和61例对照)用于重新训练旧模型,109幅图像(36例病例和73例对照)用于评估性能。
  • 所有图像由乳腺影像专科放射科医生采集和选取,每个淋巴结的良恶性性质通过严格的临床方案经超声引导下活检评估。

诊断标准与关键数值

  • 所提出方法在最优截断点的准确率为92.7%,敏感度77.8%,特异度100%。
  • 放射科医生基于超声图像的视觉淋巴结判读准确率为69.7%,敏感度41.7%,特异度83.6%。

临床应用与阅片要点

  • 作者认为该技术可能有助于无创诊断可疑反应性淋巴结患者的淋巴结状态。
  • 作者指出尚需更大规模多中心研究确认和验证结果。

局限性

  • 作者指出尚需更大规模多中心研究确认和验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study is to assess the potential of quantitative image analysis and machine learning techniques to differentiate between malignant lymph nodes and benign lymph nodes affected by reactive changes due to COVID-19 vaccination.

METHOD: In this institutional review board-approved retrospective study, we improved our previously published artificial intelligence model, by retraining it with newly collected images and testing its performance on images containing benign lymph nodes affected by COVID-19 vaccination. All the images were acquired and selected by specialized breast-imaging radiologists and the nature of each node (benign or malignant) was assessed through a strict clinical protocol using ultrasound-guided biopsies.

RESULTS: A total of 180 new images from 154 different patients were recruited: 71 images (10 cases and 61 controls) were used to retrain the old model and 109 images (36 cases and 73 controls) were used to evaluate its performance. The achieved accuracy of the proposed method was 92.7% with 77.8% sensitivity and 100% specificity at the optimal cut-off point. In comparison, the visual node inspection made by radiologists from ultrasound images reached 69.7% accuracy with 41.7% sensitivity and 83.6% specificity.

CONCLUSIONS: The results obtained in this study show the potential of the proposed techniques to differentiate between malignant lymph nodes and benign nodes affected by reactive changes due to COVID-19 vaccination. These techniques could be useful to non-invasively diagnose lymph node status in patients with suspicious reactive nodes, although larger multicenter studies are needed to confirm and validate the results.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Coronado-Gutiérrez, Ganau, Bargalló, et al. Quantitative ultrasound image analysis of axillary lymph nodes to differentiate malignancy from reactive benign changes due to COVID-19 vaccination. Eur J Radiol. 2022. PMID: 35820268. doi:10.1016/j.ejrad.2022.110438

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。