文献速递乳腺MRUS

超声弹性成像辅助BI-RADS对乳腺磁共振BI-RADS 4a类病灶的术前评估

Elastography Assisted BI-RADS in the Preoperative Breast Magnetic Resonance Imaging 4a Lesions in China.
PubMed 文献 · J Ultrasound Med · 2022-07-10

本研究纳入2017年1月至2019年12月间228个乳腺磁共振BI-RADS 4a类病灶,以病理为金标准,评估超声弹性成像辅助BI-RADS的诊断效能。当同时满足磁共振BI-RADS 4a类、超声BI-RADS 3-4a类、弹性评估为软或中等硬度、应变比<1.335、年龄≤52岁、病灶最大径≤20 mm时,不推荐超声引导下空芯针活检而推荐3-6个月短期超声随访,可使95/228个病灶避免活检,活检患者数减少41.7%。

要点

  • 磁共振BI-RADS 4a类病灶可结合超声BI-RADS分类及弹性成像参数重新评估。
  • 同时满足六项标准时不推荐活检,推荐3-6个月短期超声随访。
  • 该再评估方案使95/228个病灶避免活检,活检患者数减少41.7%。

核心结论

  • 超声弹性成像有助于磁共振BI-RADS 4a类病灶的定性,超声联合弹性成像的再评估方案可优化治疗建议。

研究设计与样本

  • 单中心研究,纳入2017年1月至2019年12月228个磁共振BI-RADS 4a类乳腺病灶,行常规超声和超声弹性成像,以病理结果为金标准。

诊断标准与关键数值

  • 同时满足磁共振BI-RADS 4a类、超声BI-RADS 3-4a类、弹性评估为软或中等硬度、应变比<1.335、年龄≤52岁、病灶最大径≤20 mm时不推荐超声引导下空芯针活检,推荐3-6个月短期超声随访,评估变化后再活检。

临床应用与阅片要点

  • 对磁共振BI-RADS 4a类病灶可结合超声BI-RADS分类、弹性评估硬度、应变比<1.335、年龄≤52岁及病灶最大径≤20 mm进行再评估,符合条件者不推荐活检而推荐3-6个月短期超声随访。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: A considerable number of benign lesions, especially category 4a lesions on Breast Imaging Reporting and Data System Magnetic Resonance Imaging (BI-RADS-MRI), were biopsied according to BI-RADS-MRI, which was a diagnostic imaging challenge. This study aimed to evaluate the diagnostic performance of ultrasound elastography (UE) assisted Breast Imaging Reporting and Data System (BI-RADS) for BI-RADS-MRI category 4a lesions.

METHODS: Between January 2017 and December 2019, 228 breast lesions categorized as BI-RADS-MRI 4a were included. Conventional ultrasound (US) and UE were performed to evaluate each lesion. Pathology results were used as the gold standard. The diagnostic performances of different UE methods and our re-assessment proposal were evaluated.

RESULTS: When BI-RADS-MRI category 4a, BI-RADS-US category 3-4a, the stiffness of soft or intermediate in elasticity assessment according to the fifth edition of the BI-RADS atlas, strain ratio < 1.335, age ≤ 52 years, and the maximum diameter of lesion ≤20 mm were simultaneously met, an ultrasound-guided empty needle biopsy was not recommended, but short-term ultrasound follow-up for 3-6 months was recommended, and biopsy was performed after changes in evaluation. In this way, 95 of 228 BI-RADS-MRI category 4a lesions avoided biopsies, and the number of patients with biopsies decreased by 41.7%.

CONCLUSIONS: UE offers benefits in the characterization of BI-RADS-MRI category 4a lesions. Ultrasound and elastography can help optimize therapy recommendations for BI-RADS-MRI category 4a lesions by our re-assessment proposal.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Tang, Wang, Gong, et al. Elastography Assisted BI-RADS in the Preoperative Breast Magnetic Resonance Imaging 4a Lesions in China. J Ultrasound Med. 2022. PMID: 35811402. doi:10.1002/jum.16055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。