研究纳入53名铝厂工人,按蒙特利尔认知评估量表分为轻度认知障碍组与正常对照组,测量脑区定量磁化率图值并分析其与量表评分及血浆铝浓度的相关性。轻度认知障碍组左侧海马、左侧齿状核、右侧黑质和左侧壳核的定量磁化率图值高于对照组,左侧海马诊断效能最佳,定量磁化率图值可能与轻度认知障碍相关。

要点

  • 轻度认知障碍组左侧海马、左侧齿状核、右侧黑质和左侧壳核定量磁化率图值高于对照组。
  • 左侧海马定量磁化率图值诊断效能最佳。
  • 定量磁化率图值与蒙特利尔认知评估量表评分呈负相关。

核心结论

  • 定量磁化率图可能作为诊断轻度认知障碍的神经影像标志物,左侧海马诊断效能最佳,轻度认知障碍组血浆铝浓度高于对照组,未发现定量磁化率图值与血浆铝浓度相关。

研究设计与样本

  • 研究收集53名铝厂工人的基本资料,按蒙特利尔认知评估量表评分分为轻度认知障碍组和正常对照组,所有参与者检测血浆铝浓度并接受磁共振成像,勾画并测量多个脑区的定量磁化率图值。

关键影像表现/征象

  • 轻度认知障碍组左侧海马、左侧齿状核、右侧黑质和左侧壳核的定量磁化率图值高于正常对照组(p<0.05)。
  • 左侧海马定量磁化率图值诊断效能最佳。
  • 定量磁化率图值与蒙特利尔认知评估量表评分呈负相关。
  • 未发现定量磁化率图值与血浆铝浓度相关(p>0.05)。

诊断标准与关键数值

  • 采用受试者工作特征曲线和z检验评估诊断效能并确定最佳参数,左侧海马诊断效能最佳。
  • 轻度认知障碍组血浆铝浓度高于正常对照组(p=0.057)。

临床应用与阅片要点

  • 定量磁化率图测量左侧海马、左侧齿状核、右侧黑质和左侧壳核的磁化率值可能有助于识别铝暴露工人的轻度认知障碍。
  • 左侧海马定量磁化率图值可能作为诊断轻度认知障碍的影像指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the diagnostic value of quantitative susceptibility mapping (QSM) in mild cognitive impairment (MCI) of aluminium (Al) workers.

MATERIALS AND METHODS: The basic data of 53 workers in an Al factory were collected and divided into the MCI group and normal control (NC) group by Montreal Cognitive Assessment (MoCA) scores. All participants were tested for plasma Al concentration and had magnetic resonance imaging (MRI). The QSM values of many areas of the brain were delineated and measured. Independent two-sample t-tests or non-parametric tests were used to compare the parameter values between the two groups. Spearman's correlation analysis was performed between QSM values, MoCA scores, and plasma Al concentration. The receiver operating characteristic curve and z test were performed to assess diagnostic efficacy and the best parameter.

RESULTS: There was no difference in age and educational level. Plasma Al concentration of the MCI group was higher than that of NC group (p=0.057). QSM values of the left hippocampus, left dentate nucleus, right substantia nigra, and left putamen in MCI group were higher than that of NC group (p<0.05), and the left hippocampus had the best diagnostic efficacy. QSM values correlated negatively with MoCA scores. No correlation was found between QSM values and plasma Al concentration (p>0.05).

CONCLUSION: QSM might be a neuroimaging marker for the diagnosis of MCI. The left hippocampus showed the best diagnostic efficacy. Plasma Al concentration of the MCI group was higher than that of the NC group. A correlation between QSM and plasma Al concentration was not found.