铁沉积对原生T1 mapping与血氧水平依赖成像评估四氯化碳中毒兔肝纤维化的影响
研究在四氯化碳诱导肝纤维化兔模型中探讨铁沉积对原生T1 mapping和血氧水平依赖(BOLD)成像检测肝纤维化的影响。肝纤维化组100只、对照组20只兔行原生T1 mapping与BOLD检查,以组织病理和肝铁含量为参考标准。BOLD参数R2*在判断肝纤维化分期进展上优于原生T1值,肝铁沉积会降低两种成像评估肝纤维化的诊断准确率,是潜在陷阱。
要点
- R2*随肝纤维化分期进展升高(r=0.75),诊断分期能力优于原生T1值。
- 区分F1-F2与F3-F4时R2*的AUC为0.91,原生T1值为0.66(p=0.01)。
- 联合肝铁含量可提高原生T1与R2*的诊断价值,尤其用于F0与F1-F2、F0与F1-F4的鉴别。
核心结论
- BOLD成像在预测和诊断肝纤维化分期进展方面优于原生T1 mapping。
- 肝铁沉积导致诊断准确率下降,是BOLD成像和原生T1 mapping评估肝纤维化的潜在陷阱。
研究设计与样本
- 动物实验:肝纤维化组100只兔经皮下注射50%四氯化碳油溶液造模,对照组20只正常兔。
- 行原生T1 mapping与BOLD检查,分析T1native和R2*定量参数,采用ROC与多元logistic回归分析。
- 以组织病理学结果和肝铁含量(LIC)为参考标准。
关键影像表现/征象
- T1native(r=0.47)、R2*(r=0.75)和LIC(r=0.61)均随肝纤维化分期进展而升高(p<0.001)。
诊断标准与关键数值
- 组织病理诊断肝纤维化分期F0、F1、F2、F3、F4的兔分别为18、17、16、18、15只。
- 区分F1-F2与F3-F4时,R2*的AUC为0.91,原生T1值的AUC为0.66(p=0.01)。
- 诊断F0与F1-F2时,T1native+LIC的AUC为0.90,LIC的AUC为0.70(p=0.01)。
- 诊断F0与F1-F4时,T1native+LIC的AUC为0.93,LIC的AUC为0.77(p=0.01)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aimed to explore the effect of iron deposition on native T1 mapping and blood oxygen level-dependent (BOLD) imaging in detecting liver fibrosis (LF) in a rabbit model.
MATERIALS AND METHODS: An LF group (n = 100) was established by subcutaneously injecting 50% carbon tetrachloride (CCl4) oil solution, and 20 normal rabbits composed a control group. Native T1 mapping and BOLD were performed, and the T1native and R2* quantitative parameters were analyzed by receiver operating characteristic (ROC) and multiple logistic regression analyses, with histopathological results and liver iron content (LIC) serving as reference standards.
RESULTS: In total, 18, 17, 16, 18, and 15 rabbits were histopathologically diagnosed with LF stages F0, F1, F2, F3, and F4, respectively. T1native (r = 0.47), R2* (r = 0.75) and LIC (r = 0.61) increased with LF stage progression (p < 0.001). Compared to T1native values, R2* performed better in diagnosing the LF stage, especially for distinguishing F1-F2 from F3-F4 (AUC = 0.66 vs. 0.91, p = 0.01). Combined with the LIC, both T1native and R2* showed improved diagnostic value in comparison to the individual imaging techniques, particularly for diagnosing F0 vs. F1-F2 and F0 vs. F1-F4, with AUC values of 0.90 vs. 0.70 (p = 0.01) and 0.93 vs. 0.77 (p = 0.01) for T1native + LIC vs. LIC, respectively.
CONCLUSION: BOLD imaging performed better than native T1 mapping in predicting and diagnosing LF stage progression. The decrease in diagnostic accuracy caused by the deposition of liver iron is a potential pitfall in the assessment of LF with BOLD imaging and native T1 mapping.
引用
- Zou, Liu, Du, et al. Effect of Iron Deposition on Native T1 Mapping and Blood Oxygen Level Dependent for the Assessment of Liver Fibrosis in Rabbits With Carbon Tetrachloride Intoxication. Acad Radiol. 2022. PMID: 35811218. doi:10.1016/j.acra.2022.06.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。