文献速递腹部MR

铁沉积对原生T1 mapping与血氧水平依赖成像评估四氯化碳中毒兔肝纤维化的影响

Effect of Iron Deposition on Native T1 Mapping and Blood Oxygen Level Dependent for the Assessment of Liver Fibrosis in Rabbits With Carbon Tetrachloride Intoxication.
PubMed 文献 · Acad Radiol · 2022-07-08

研究在四氯化碳诱导肝纤维化兔模型中探讨铁沉积对原生T1 mapping和血氧水平依赖(BOLD)成像检测肝纤维化的影响。肝纤维化组100只、对照组20只兔行原生T1 mapping与BOLD检查,以组织病理和肝铁含量为参考标准。BOLD参数R2*在判断肝纤维化分期进展上优于原生T1值,肝铁沉积会降低两种成像评估肝纤维化的诊断准确率,是潜在陷阱。

要点

  • R2*随肝纤维化分期进展升高(r=0.75),诊断分期能力优于原生T1值。
  • 区分F1-F2与F3-F4时R2*的AUC为0.91,原生T1值为0.66(p=0.01)。
  • 联合肝铁含量可提高原生T1与R2*的诊断价值,尤其用于F0与F1-F2、F0与F1-F4的鉴别。

核心结论

  • BOLD成像在预测和诊断肝纤维化分期进展方面优于原生T1 mapping。
  • 肝铁沉积导致诊断准确率下降,是BOLD成像和原生T1 mapping评估肝纤维化的潜在陷阱。

研究设计与样本

  • 动物实验:肝纤维化组100只兔经皮下注射50%四氯化碳油溶液造模,对照组20只正常兔。
  • 行原生T1 mapping与BOLD检查,分析T1native和R2*定量参数,采用ROC与多元logistic回归分析。
  • 以组织病理学结果和肝铁含量(LIC)为参考标准。

关键影像表现/征象

  • T1native(r=0.47)、R2*(r=0.75)和LIC(r=0.61)均随肝纤维化分期进展而升高(p<0.001)。

诊断标准与关键数值

  • 组织病理诊断肝纤维化分期F0、F1、F2、F3、F4的兔分别为18、17、16、18、15只。
  • 区分F1-F2与F3-F4时,R2*的AUC为0.91,原生T1值的AUC为0.66(p=0.01)。
  • 诊断F0与F1-F2时,T1native+LIC的AUC为0.90,LIC的AUC为0.70(p=0.01)。
  • 诊断F0与F1-F4时,T1native+LIC的AUC为0.93,LIC的AUC为0.77(p=0.01)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aimed to explore the effect of iron deposition on native T1 mapping and blood oxygen level-dependent (BOLD) imaging in detecting liver fibrosis (LF) in a rabbit model.

MATERIALS AND METHODS: An LF group (n = 100) was established by subcutaneously injecting 50% carbon tetrachloride (CCl4) oil solution, and 20 normal rabbits composed a control group. Native T1 mapping and BOLD were performed, and the T1native and R2* quantitative parameters were analyzed by receiver operating characteristic (ROC) and multiple logistic regression analyses, with histopathological results and liver iron content (LIC) serving as reference standards.

RESULTS: In total, 18, 17, 16, 18, and 15 rabbits were histopathologically diagnosed with LF stages F0, F1, F2, F3, and F4, respectively. T1native (r = 0.47), R2* (r = 0.75) and LIC (r = 0.61) increased with LF stage progression (p < 0.001). Compared to T1native values, R2* performed better in diagnosing the LF stage, especially for distinguishing F1-F2 from F3-F4 (AUC = 0.66 vs. 0.91, p = 0.01). Combined with the LIC, both T1native and R2* showed improved diagnostic value in comparison to the individual imaging techniques, particularly for diagnosing F0 vs. F1-F2 and F0 vs. F1-F4, with AUC values of 0.90 vs. 0.70 (p = 0.01) and 0.93 vs. 0.77 (p = 0.01) for T1native + LIC vs. LIC, respectively.

CONCLUSION: BOLD imaging performed better than native T1 mapping in predicting and diagnosing LF stage progression. The decrease in diagnostic accuracy caused by the deposition of liver iron is a potential pitfall in the assessment of LF with BOLD imaging and native T1 mapping.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Zou, Liu, Du, et al. Effect of Iron Deposition on Native T1 Mapping and Blood Oxygen Level Dependent for the Assessment of Liver Fibrosis in Rabbits With Carbon Tetrachloride Intoxication. Acad Radiol. 2022. PMID: 35811218. doi:10.1016/j.acra.2022.06.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。