PubMed 文献 · Acad Radiol · 2022-07-07

本研究纳入148例患者共156个实性卵巢肿瘤(良性86个、恶性70个),提取12个临床特征和1612个影像组学特征,用Lasso筛选特征并以XGB算法构建临床模型、影像组学模型和联合模型。测试集中联合模型表现最佳,AUC为0.954(95%CI 0.862-1.0,p<0.01),准确度0.839、精确度0.909、敏感度0.714。结论认为基于机器学习的影像组学可帮助放射科医生鉴别良恶性实性卵巢肿瘤。

要点

  • 联合模型在测试集鉴别良恶性实性卵巢肿瘤的AUC为0.954(95%CI 0.862-1.0,p<0.01)。
  • 测试集联合模型准确度0.839、精确度0.909、敏感度0.714。
  • 测试集临床模型AUC为0.847(95%CI 0.707-0.986,p<0.01),影像组学模型AUC为0.807(95%CI 0.652-0.961,p<0.05)。

核心结论

  • 基于机器学习的影像组学可帮助放射科医生鉴别良恶性实性卵巢肿瘤。
  • 联合临床与影像组学特征的联合模型在测试集预测结果最佳,AUC为0.954(95%CI 0.862-1.0,p<0.01)。

研究设计与样本

  • 本研究纳入148例患者共156个实性卵巢肿瘤,其中良性86个、恶性70个。
  • 数据集按8:2比例采用分层随机抽样分为训练集和测试集。
  • 从每个肿瘤提取12个临床特征和1612个影像组学特征,采用Lasso筛选特征。
  • 使用XGB算法构建临床模型、影像组学模型和联合模型三种分类模型。

诊断标准与关键数值

  • 测试集临床模型AUC为0.847(95%CI 0.707-0.986,p<0.01),准确度0.774、精确度0.769、敏感度0.714。
  • 测试集影像组学模型AUC为0.807(95%CI 0.652-0.961,p<0.05),准确度0.677、精确度0.643、敏感度0.643。
  • 测试集联合模型AUC为0.954(95%CI 0.862-1.0,p<0.01),准确度0.839、精确度0.909、敏感度0.714。

临床应用与阅片要点

  • 作者认为基于机器学习的影像组学可帮助放射科医生鉴别良恶性实性卵巢肿瘤。
  • 三种模型在训练集和测试集中鉴别良恶性实性卵巢肿瘤均获得良好性能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop and validate a combined model integrating clinical and radiomic features to non-invasive discriminate between the benign and malignant solid ovarian tumors.

MATERIALS AND METHODS: A total of 148 patients with 156 solid ovarian tumors (86 benign and 70 malignant tumors) were included in this study. The dataset was split into the training and the test set with a ratio of 8:2 using stratified random sampling. 12 clinical features and 1612 radiomic features were extracted from each tumor. These features were selected by least absolute shrinkage and selection operator (Lasso). Three classification models were built using extreme gradient boosting (XGB) algorithm: clinical model, radiomic model, combined model. The area under the receiver operating characteristic curve (AUC), accuracy, precision and sensitivity were analyzed to evaluate the performance of these models.

RESULTS: All of the three models obtained good performances in differentiating benign with malignant solid ovarian tumors in both training and test sets. The AUC, accuracy, precision, sensitivity of clinical model and radiomic model in test set were 0.847 (95% confidence interval (CI), 0.707-0.986, p <0.01), 0.774, 0.769, 0.714, and 0.807 (95%CI, 0.652-0.961, p <0.05), 0.677, 0.643, 0.643, respectively. Combined model had the best prediction results, the AUC, accuracy, precision and sensitivity were 0.954 (95%CI, 0.862-1.0, p <0.01), 0.839, 0.909 and 0.714 in test set.

CONCLUSION: Radiomics based on machine learning can be helpful for radiologists in differentiating the benign and malignant solid ovarian tumors.