低管电压低碘量肝动脉造影CT在经动脉化疗栓塞前检测肝细胞癌的临床影响
研究纳入23例患者共89个肝细胞癌,采用双期扫描技术(80 kVp与135 kVp)配合30 ml低浓度碘对比剂(75 mgI/ml)行肝动脉造影CT,比较两种管电压下诊断肝细胞癌的敏感度、阳性预测值、病灶-肝对比比及客观噪声。80 kVp较135 kVp辐射剂量指数体积降低(21.3 mGy vs 9.4 mGy,P<0.001),总体敏感度提高(0.787 vs 0.730),阳性预测值降低(0.712 vs 0.756),两期病灶-肝对比比均显著升高,客观噪声亦显著升高。
要点
- 80 kVp肝动脉造影CT较135 kVp辐射剂量指数体积降低(21.3 mGy vs 9.4 mGy,P<0.001)。
- 80 kVp总体诊断敏感度0.787 vs 135 kVp 0.730,阳性预测值0.712 vs 0.756。
- 80 kVp两期病灶-肝对比比均显著高于135 kVp,但客观噪声亦显著升高。
核心结论
- 80 kVp肝动脉造影CT使用较低剂量碘对比剂,较135 kVp相同碘剂量方案提高了诊断敏感度并降低了辐射剂量,但阳性预测值有所下降。
研究设计与样本
- 研究纳入23例患者(体重指数23.6 ± 2.6 kg/m2)共89个肝细胞癌,采用双期扫描技术(80 kVp和135 kVp)配合30 ml低浓度碘对比剂(75 mgI/ml)行肝动脉造影CT,由3名放射科医生独立阅片诊断肝细胞癌并记录置信度评分及图像质量评价,另由1名非阅片放射科医生测量病灶-肝对比比和客观噪声。
关键影像表现/征象
- 80 kVp肝动脉造影CT第一期的病灶-肝对比比为3.1,显著高于135 kVp的2.0(P=0.008)。
- 80 kVp肝动脉造影CT第二期的病灶-肝对比比为3.1,显著高于135 kVp的2.3(P=0.016)。
- 80 kVp肝动脉造影CT第二期的客观噪声为16.9 ± 5.2,显著高于135 kVp的15.0 ± 7.3(P=0.046)。
诊断标准与关键数值
- 80 kVp肝动脉造影CT诊断肝细胞癌的总体敏感度为0.787,阳性预测值为0.712。
- 135 kVp肝动脉造影CT诊断肝细胞癌的总体敏感度为0.730,阳性预测值为0.756。
- 80 kVp肝动脉造影CT的辐射剂量指数体积为9.4 mGy,135 kVp为21.3 mGy(P<0.001)。
临床应用与阅片要点
- 80 kVp肝动脉造影CT可在降低辐射剂量的同时提高肝细胞癌诊断敏感度,但阳性预测值较135 kVp降低。
- 80 kVp图像客观噪声较135 kVp增高,阅片时需注意噪声对图像质量的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study aimed to evaluate the clinical impact of low tube voltage computed tomography (CT) during hepatic arteriography (CTHA) using low iodine contrast to detect hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: CTHA images were obtained using a dual-spin technique (80 kVp and 135 kVp) with 30 ml of low-dose iodine contrast (75 mgI/ml). Three radiologists reviewed 135 kVp and 80 kVp CTHA images to diagnose HCC, recording their confidence scores and evaluations of sharpness, noise, artifact, and overall image quality. Lesion-to-liver contrast ratios and objective noise were measured by a non-reader radiologist.
RESULTS: We included 23 patients (body mass index, 23.6 ± 2.6 kg/m2) with 89 HCCs. The mean radiation dose index volume was 21.3 mGy at 135 kVp and 9.4 mGy at 80 kVp (P < 0.001). The overall sensitivity and positive predictive value for diagnosing HCCs at 80 kVp vs. 135 kVp were 0.787 vs. 0.730 and 0.712 vs. 0.756, respectively. The lesion-to-liver contrast ratio at 80 kVp was significantly higher than at 135 kVp in the first (3.1 vs. 2.0; P = 0.008) and second phase (3.1 vs. 2.3; P = 0.016). Objective noise was significantly higher at 80 kVp than at 135 kVp in the first (15. 6 ± 4.9 vs. 11.0 ± 3.1; P < 0.001) and second (16.9 ± 5.2 vs. 15.0 ± 7.3; P = 0.046) phases.
CONCLUSION: An 80 kVp CTHA, with lower-dose iodine, improved the sensitivity and reduced the radiation dose, despite a decreased positive predictive value in comparison with a 135-kVp CTHA with the same iodine dose.
引用
- Inoue, Uemura, Takaki, et al. Clinical impact of low tube voltage computed tomography during hepatic arteriography with low iodine to detect hepatocellular carcinoma before transarterial chemoembolization. Eur J Radiol. 2022. PMID: 35809489. doi:10.1016/j.ejrad.2022.110420
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。