文献速递腹部MR

基于深度学习的超分辨率与部分傅里叶重建联合用于3特斯拉腹部磁共振梯度回波序列:缩短屏气时间并提高图像锐度和病灶显著性

Combined Deep Learning-based Super-Resolution and Partial Fourier Reconstruction for Gradient Echo Sequences in Abdominal MRI at 3 Tesla: Shortening Breath-Hold Time and Improving Image Sharpness and Lesion Conspicuity.
PubMed 文献 · Acad Radiol · 2022-07-06

回顾性纳入32例患者,在3T腹部T1加权VIBE序列上用深度学习超分辨率联合部分傅里叶重建(VIBESR)与标准重建(VIBESD)对比。VIBESR屏气时间约缩短13.6%,腹部器官和血管锐度更优,图像对比、噪声、整体质量和诊断信心无差异,肝病灶显著性更优,病灶检出率无显著差异。

要点

  • VIBESR屏气时间11.9±1.2秒 vs VIBESD 13.9±1.4秒,缩短约13.6%(p<0.001)。
  • VIBESR腹部器官和血管锐度优于VIBESD(p值0.005至<0.001)。
  • VIBESR肝病灶显著性优于VIBESD(p值0.046至<0.001),病灶检出率无显著差异。

核心结论

  • 基于深度学习的超分辨率联合层面相位编码方向部分傅里叶重建可缩短屏气时间,并提高3T腹部T1加权梯度回波序列的图像锐度和病灶显著性,同时不损害图像质量或诊断信心。

研究设计与样本

  • 回顾性研究,纳入2021年3月至6月间32例因临床指征行3T腹部增强VIBE磁共振成像的患者,采用标准VIBESD序列为参考标准,并用同一原始数据回顾性重建VIBESR图像,由4名放射科医生盲法独立分析。

关键影像表现/征象

  • VIBESR图像上腹部器官和血管锐度被所有读者评为优于VIBESD(p值0.005至<0.001)。
  • VIBESR与VIBESD在图像对比、噪声、整体图像质量和诊断信心上无差异证据(p>0.05)。
  • VIBESR上肝病灶显著性优于VIBESD(p值0.046至<0.001),但病灶大小无显著差异。

诊断标准与关键数值

  • VIBESR屏气时间11.9±1.2秒 vs VIBESD 13.9±1.4秒,缩短约13.6%(p<0.001)。
  • 所有对比期相读者间一致性Fleiss Kappa>0.7;病灶大小读者间一致性ICC>0.9。
  • 共分析13个肝病灶,VIBESD与VIBESR之间肝病灶检出率无统计学显著差异。

临床应用与阅片要点

  • 在日常腹部T1加权梯度回波序列中,可用VIBESR缩短屏气时间并改善器官和血管锐度及肝病灶显著性。
  • VIBESR不损害图像对比、噪声、整体图像质量和诊断信心,肝病灶检出率与标准序列无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate the impact of a prototypical deep learning-based super-resolution reconstruction algorithm tailored to partial Fourier acquisitions on acquisition time and image quality for abdominal T1-weighted volume-interpolated breath-hold examination (VIBESR) at 3 Tesla. The standard T1-weighted images were used as the reference standard (VIBESD).

MATERIALS AND METHODS: Patients with diverse abdominal pathologies, who underwent a clinically indicated contrast-enhanced abdominal VIBE magnetic resonance imaging at 3T between March and June 2021 were retrospectively included. Following the acquisition of the standard VIBESD sequences, additional images for the non-contrast, dynamic contrast-enhanced and post-contrast T1-weighted VIBE acquisition were retrospectively reconstructed using the same raw data and employing a prototypical deep learning-based super-resolution reconstruction algorithm. The algorithm was designed to enhance edge sharpness by avoiding conventional k-space filtering and to perform a partial Fourier reconstruction in the slice phase-encoding direction for a predefined asymmetric sampling ratio. In the retrospective reconstruction, the asymmetric sampling was realized by omitting acquired samples at the end of the acquisition and therefore corresponding to a shorter acquisition. Four radiologists independently analyzed the image datasets (VIBESR and VIBESD) in a blinded manner. Outcome measures were: sharpness of abdominal organs, sharpness of vessels, image contrast, noise, hepatic lesion conspicuity and size, overall image quality and diagnostic confidence. These parameters were statistically compared and interrater reliability was computed using Fleiss' Kappa and intraclass correlation coefficient (ICC). Finally, the rate of detection of hepatic lesions was documented and was statistically compared using the paired Wilcoxon test.

RESULTS: A total of 32 patients aged 59 ± 16 years (23 men (72%), 9 women (28%)) were included. For VIBESR, breath-hold time was significantly reduced by approximately 13.6% (VIBESR 11.9 ± 1.2 seconds vs. VIBESD: 13.9 ± 1.4 seconds, p < 0.001). All readers rated sharpness of abdominal organs, sharpness of vessels to be superior in images with VIBESR (p values ranged between p = 0.005 and p < 0.001). Despite reduction of acquisition time, image contrast, noise, overall image quality and diagnostic confidence were not compromised, as there was no evidence of a difference between VIBESR and VIBESD (p > 0.05). The inter-reader agreement was substantial with a Fleiss' Kappa of >0.7 in all contrast phases. A total of 13 hepatic lesions were analyzed. The four readers observed a superior lesion conspicuity in VIBESR than in VIBESD (p values ranged between p = 0.046 and p < 0.001). In terms of lesion size, there was no significant difference between VIBESD and VIBESR for all readers. Finally, there was an excellent inter-reader agreement regarding lesion size (ICC > 0.9). For all readers, no statistically significant difference was observed regarding detection of hepatic lesions between VIBESD and VIBESR.

CONCLUSION: The deep learning-based super-resolution reconstruction with partial Fourier in the slice phase-encoding direction enabled a reduction of breath-hold time and improved image sharpness and lesion conspicuity in T1-weighted gradient echo sequences in abdominal magnetic resonance imaging at 3 Tesla. Faster acquisition time without compromising image quality or diagnostic confidence was possible by using this deep learning-based reconstruction technique.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Almansour, Herrmann, Gassenmaier, et al. Combined Deep Learning-based Super-Resolution and Partial Fourier Reconstruction for Gradient Echo Sequences in Abdominal MRI at 3 Tesla: Shortening Breath-Hold Time and Improving Image Sharpness and Lesion Conspicuity. Acad Radiol. 2022. PMID: 35810067. doi:10.1016/j.acra.2022.06.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。