文献速递妇产影像介入MRUS

超声引导高强度聚焦超声消融子宫肌瘤的学习曲线:一项多中心前瞻性研究

Learning Curve of USgHIFU Ablation for Uterine Fibroids: A Multi-Center Prospective Study.
PubMed 文献 · J Ultrasound Med · 2022-07-08

多中心前瞻性研究纳入12名医师和720例病例,学习组(6名无HIFU经验医师,360例)与对照组(6名有经验医师,360例)各半,用累积和法学习曲线分析。两组无灌注体积比匹配,有经验医师92.52%(16.06)vs 无经验医师93.82%(16.95),无重大并发症。学习组在70%和80%标准下分别于第11例和第16例掌握技术。

要点

  • 无HIFU经验医师经培训后无灌注体积比达93.82%,与有经验医师的92.52%相当。
  • 以无灌注体积比70%为培训合格标准时,学习组于第11例掌握技术。
  • 以无灌注体积比80%为更严格培训标准时,学习组于第16例掌握技术。

核心结论

  • HIFU技术操作稳定、安全性好、有效且易学,无灌注体积比70%可作为培训合格的适宜指标。

研究设计与样本

  • 多中心前瞻性研究,共12名医师和720例病例,学习组与对照组各6名医师、360例;学习组为无HIFU经验医师,对照组为有经验医师;无灌注体积比由增强磁共振成像评估。

诊断标准与关键数值

  • 技术失败定义为子宫肌瘤无灌注体积比<70%和/或重大并发症;无灌注体积比<80%设为更严格的培训合格标准;学习曲线采用累积和法分析。

临床应用与阅片要点

  • 无灌注体积比70%可作为培训合格指标,无灌注体积比≥80%在安全性不受影响的前提下具有良好前景。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To verify the stability of high-intensity focused ultrasound (HIFU) technology and the feasibility of training programs with learning curve cumulative summation (LC-CUSUM).

METHODS: A total of 12 physicians and 720 cases were equally assigned to the learning group and the control group, with 6 physicians and 360 cases per group. The learning group was treated by physicians without HIFU experience and the control group was treated by experienced physicians. Nonperfused volume (NPV) ratio was assessed by contrast-enhanced magnetic resonance imaging. Technical failure was defined as NPV ratio of uterine fibroids <70% and/or major complication, while <80% was set as a stricter standard of training qualification. LC-CUSUM was used to analyze the learning curve.

RESULTS: Physicians with or without HIFU experience in both groups achieved matchable NPV ratios, where a NPV ratio of 92.52% (16.06) was achieved by experienced physicians and 93.82% (16.95) by inexperienced physicians. No major complication was observed. The results of LC-CUSUM analysis showed that, with the standards of the NPV ratio of 70% or 80%, the learning group mastered the technique on the 11th case and the 16th case, respectively, while the control group was stable.

CONCLUSIONS: HIFU technology stayed stable in operation, with good safety and sound effectiveness, and was easy to learn. NPV ratio of 70% was considered as an appropriate indicator of training qualification. HIFU has remarkable prospects in achieving a NPV ratio of ≥80% without safety being compromised.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Liu, Zhang, Gong, et al. Learning Curve of USgHIFU Ablation for Uterine Fibroids: A Multi-Center Prospective Study. J Ultrasound Med. 2022. PMID: 35801618. doi:10.1002/jum.16056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。