卵巢囊腺纤维瘤的磁共振成像特征:基于O-RADS词典并纳入扩散加权与灌注成像的更新
研究纳入2019年10月至2021年12月经组织学证实的21例卵巢囊腺纤维瘤(20例良性,1例交界性伴腺癌退变),按O-RADS词典分析MRI形态、灌注时间-强度曲线及DWI表现,并评估O-RADS MRI风险评分。实性组织多呈缓慢渐进性强化(I型曲线),对应O-RADS 2或3分;唯一恶性病灶呈II型曲线且DWI受限,评为O-RADS 4分。O-RADS评分能正确区分良恶性肿块。
要点
- 囊腺纤维瘤实性组织在灌注成像上多表现为缓慢渐进性强化的I型曲线,对应O-RADS 2或3分。
- 唯一恶性病灶表现为II型曲线并伴DWI扩散受限,O-RADS评分为4分。
- O-RADS MRI评分系统在该组病例中正确地将肿块分类为良性或恶性。
核心结论
- O-RADS MRI评分能正确区分囊腺纤维瘤的良恶性,灌注时间-强度曲线与DWI序列在鉴别中起关键作用。
研究设计与样本
- 回顾性纳入2019年10月至2021年12月因经阴道超声结论不明确而行MRI检查、术后组织学证实为囊腺纤维瘤的全部患者,共21个病灶。
关键影像表现/征象
- 囊腺纤维瘤实性组织在灌注加权成像上多呈缓慢渐进性强化,即I型时间-强度曲线。
- 唯一恶性病灶呈II型时间-强度曲线,并在DWI上表现为扩散受限。
诊断标准与关键数值
- 按O-RADS词典,I型曲线病灶评为O-RADS 2或3分。
- 唯一恶性病灶因II型曲线及DWI扩散受限评为O-RADS 4分。
临床应用与阅片要点
- 阅片时可结合灌注时间-强度曲线类型与DWI表现对囊腺纤维瘤进行O-RADS评分。
- 本研究中O-RADS评分正确区分了良性与恶性肿块。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Cystadenofibroma (CAF) is a rare tumour of the ovary that can be confused with a borderline or malignant lesion due to its morphological characteristics. The study aims to analyse the MRI (magnetic resonance imaging) features of histologically proven ovarian cystadenofibromas according to lexicon-based and O-RADS (Ovarian-Adnexal Reporting and Data System) descriptors, with particular attention to time-intensity curves (TIC) and Diffusion-Weighted sequences (DWI); we also wanted to test the performance of O-RADS MRI risk stratification system in this particular subgroup of patients.
METHODS: We have included all patients who performed MR between October 2019 and December 2021 after an inconclusive trans-vaginal ultrasound. All patients underwent surgery with histological results of CAF. According to the O-RADS lexicon, we reported the morphological characteristics of each lesion and their appearance in the perfusion-weighted imaging (PWI) and DWI sequences. We assessed the risk of malignancy for each lesion through O-RADS MRI score.
RESULTS: Twenty-one histologically proven CAF were analysed, of which 20 benign and one borderline with degeneration into adenocarcinoma. We described the typical morphological characteristics of CAF according to lexicon-based and O-RADS descriptors. Analysis of time-intensity curves (TIC) in PWI sequences showed a slow and progressive enhancement of solid tissue (type I curve), configuring an O-RADS score of 2 or 3, except for the only malignant lesion that showed a type II curve and restriction in DWI (O-RADS 4).
CONCLUSIONS: Our study is the largest comprising PWI and DWI sequences, highlighting their pivotal role. O-RADS score correctly classified the masses as benign or malignant.
引用
- Avesani, Elia, Anghelone, et al. Features of cystadenofibroma on magnetic resonance imaging: an update using the O-RADS lexicon and considering diffusion-weighted and perfusion imaging. Eur J Radiol. 2022. PMID: 35797789. doi:10.1016/j.ejrad.2022.110429
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。