深度学习重建加速腹部弥散加权成像的临床可行性:与传统弥散加权成像的比较
回顾性纳入74例连续接受3 T腹部MRI的患者,比较深度学习重建DWI(DL DWI)与传统DWI的图像质量和采集时间。DL DWI平均采集时间216.87±49.23秒,显著短于传统DWI的358.69±105.93秒(P<0.001),所有定性图像质量参数评分均更高(P<0.001),肝实质及局灶性病变ADC值更低,各肝区ADC值标准差显著更低(均P<0.001)。
要点
- DL DWI平均采集时间216.87±49.23秒,较传统DWI的358.69±105.93秒显著缩短(P<0.001)。
- DL DWI所有定性图像质量参数评分均高于传统DWI(P<0.001)。
- DL DWI肝实质及局灶性病变ADC值低于传统DWI,各肝区ADC值标准差显著更低(均P<0.001)。
核心结论
- DL DWI在临床常规中可行,图像质量改善且扫描时间显著缩短。
研究设计与样本
- 回顾性纳入74例连续接受3 T腹部MRI的患者,比较传统DWI与DL DWI两种序列,由两名放射科医生评分图像质量并测量ADC。
关键影像表现/征象
- DL DWI所有定性图像质量参数(整体图像质量、解剖锐利度与细节、伪影、噪声、病变可见度)评分均高于传统DWI(P<0.001)。
- DL DWI肝内ADC值分布较传统DWI更均匀,左上部段除外。
- DL DWI肝实质和局灶性肝病变的ADC值均低于传统DWI。
诊断标准与关键数值
- DL DWI平均采集时间216.87±49.23秒,传统DWI为358.69±105.93秒,DL DWI显著更短(P<0.001)。
- 所有肝区ADC值标准差DL DWI均显著低于传统DWI(均P<0.001)。
- ADC测量位置为肝实质六个位置及局灶性病变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the clinical feasibility of accelerated deep learning-reconstructed diffusion weighted imaging (DWI) and to compare its image quality and acquisition time with those of conventional DWI.
METHODS: Seventy-four consecutive patients who underwent 3 T abdominal magnetic resonance imaging (MRI) were retrospectively enrolled. DWI were acquired using both conventional DWI and DWI with deep-learning reconstruction (DL DWI). Image quality (overall image quality, anatomic sharpness and details, artifacts, noise, and lesion conspicuity) was scored by two radiologists and compared between two DWI sequences. The apparent diffusion coefficient (ADC) was measured in six locations of the liver parenchyma and focal lesions and compared between two DWI sequences.
RESULTS: The mean acquisition time for the DL DWI (216.87 ± 49.23 sec) was significantly shorter (P < 0.001) than for conventional DWI (358.69 ± 105.93 sec). DL DWI achieved higher scores than conventional DWI for all qualitative image quality parameters (P < 0.001). DL DWI had a more homogeneous distribution of ADC values throughout the liver, except for the left superior section, compared with conventional DWI. The standard deviations of the ADC values for all hepatic areas were significantly lower in DL DWI than in conventional DWI (all, P < 0.001). The ADC values for the liver parenchyma and focal hepatic lesions were lower in DL DWI than in conventional DWI.
CONCLUSIONS: DL DWI is a feasible acquisition technique in clinical routines and provides improved image quality and simultaneously significant reduction in scan time compared with conventional DWI.
引用
- Bae, Hwang, Hong, et al. Clinical feasibility of accelerated diffusion weighted imaging of the abdomen with deep learning reconstruction: Comparison with conventional diffusion weighted imaging. Eur J Radiol. 2022. PMID: 35797791. doi:10.1016/j.ejrad.2022.110428
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。