文献速递心血管外周血管CTPET

18F-氟化钠正电子发射断层显像与计算机断层显像在急性主动脉综合征中的应用

18F-Sodium Fluoride Positron Emission Tomography and Computed Tomography in Acute Aortic Syndrome.
PubMed 文献 · JACC Cardiovasc Imaging · 2022-03-16

概念验证研究纳入47例急性主动脉综合征患者和20例对照,行18F-NaF PET/CT血管成像,发现患者主动脉摄取增高(TBRmax 2.02±0.42 vs 1.36±0.39,P<0.001),假腔摄取与主动脉增长相关,外壁摄取与主要不良主动脉事件相关(HR 8.5)。

要点

  • 急性主动脉综合征患者主动脉18F-NaF摄取较对照增高(TBRmax 2.02±0.42 vs 1.36±0.39,P<0.001)。
  • 内膜撕裂处18F-NaF摄取增强27.5%(P<0.001)。
  • 外壁摄取与主要不良主动脉事件相关(HR 8.5,95%CI 1.4-50.4,P=0.019)。

核心结论

  • 在急性主动脉综合征患者中,18F-NaF摄取在疾病活动部位增强,并与主动脉增长和临床事件相关;18F-NaF PET/CT有望作为无创的疾病严重程度和未来风险标志物。

研究设计与样本

  • 概念验证研究,纳入47例急性主动脉综合征患者(主动脉夹层或壁内血肿)和20例对照,行主动脉18F-NaF PET/CT血管成像,测量最病变段摄取并以最大组织本底比(TBRmax)表示,随访45±13个月比较主动脉大小变化和主要不良主动脉事件。

关键影像表现/征象

  • 18F-NaF摄取与组织学定义的微钙化及弹性蛋白破坏区域共定位。
  • 内膜撕裂处18F-NaF摄取增强27.5%(P<0.001)。
  • 假腔摄取与主动脉增长相关(+7.1 mm/年,P=0.011)。
  • 外壁摄取与主要不良主动脉事件相关(HR 8.5,95%CI 1.4-50.4,P=0.019)。

诊断标准与关键数值

  • 主动脉18F-NaF摄取在最病变段测量,以最大组织本底比(TBRmax)表示。
  • 急性主动脉综合征患者TBRmax为2.02±0.42(n=47),对照组为1.36±0.39(n=20),P<0.001。

临床应用与阅片要点

  • 18F-NaF PET/CT所示外壁摄取可能与主要不良主动脉事件风险相关(HR 8.5,95%CI 1.4-50.4)。
  • 假腔18F-NaF摄取与主动脉增长相关(+7.1 mm/年,P=0.011)。
  • 作者认为18F-NaF PET/CT有望作为急性主动脉综合征疾病严重程度和未来风险的无创标志物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Acute aortic syndrome is associated with aortic medial degeneration. 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) detects microscopic tissue calcification as a marker of disease activity.

OBJECTIVES: In a proof-of-concept study, this investigation aimed to establish whether 18F-NaF PET combined with computed tomography (CT) angiography could identify aortic medial disease activity in patients with acute aortic syndrome.

METHODS: Patients with aortic dissection or intramural hematomas and control subjects underwent 18F-NaF PET/CT angiography of the aorta. Aortic 18F-NaF uptake was measured at the most diseased segment, and the maximum value was corrected for background blood pool activity (maximum tissue-to-background ratio [TBRmax]). Radiotracer uptake was compared with change in aortic size and major adverse aortic events (aortic rupture, aorta-related death, or aortic repair) over 45 ± 13 months.

RESULTS: Aortic 18F-NaF uptake co-localized with histologically defined regions of microcalcification and elastin disruption. Compared with control subjects, patients with acute aortic syndrome had increased 18F-NaF uptake (TBRmax: 1.36 ± 0.39 [n = 20] vs 2.02 ± 0.42 [n = 47] respectively; P < 0.001) with enhanced uptake at the site of intimal disruption (+27.5%; P < 0.001). 18F-NaF uptake in the false lumen was associated with aortic growth (+7.1 mm/year; P = 0.011), and uptake in the outer aortic wall was associated with major adverse aortic events (HR: 8.5 [95% CI: 1.4-50.4]; P = 0.019).

CONCLUSIONS: In patients with acute aortic syndrome, 18F-NaF uptake was enhanced at sites of disease activity and was associated with aortic growth and clinical events. 18F-NaF PET/CT holds promise as a noninvasive marker of disease severity and future risk in patients with acute aortic syndrome. (18F Sodium Fluoride PET/CT in Acute Aortic Syndrome [FAASt]; NCT03647566).

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Syed, Fletcher, Debono, et al. 18F-Sodium Fluoride Positron Emission Tomography and Computed Tomography in Acute Aortic Syndrome. JACC Cardiovasc Imaging. 2022. PMID: 35798405. doi:10.1016/j.jcmg.2022.01.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。