文献速递胸部介入CT

术前CT引导下基准标记放置用于肺结节手术定位

Preoperative CT-guided Fiducial Marker Placement for Surgical Localization of Pulmonary Nodules.
PubMed 文献 · Radiol Cardiothorac Imaging · 2022-02-10

单中心回顾性分析2014至2020年198例次术前CT引导下基准标记放置,共定位205个肺结节(平均大小10 mm±4)。技术成功率98.5%(195/198),无主要并发症,外科定位失败率0.5%(1例)。结论认为该操作安全、有效且外科定位失败率低。

要点

  • CT引导下基准标记放置技术成功率为98.5%(195/198),无主要并发症。
  • 外科定位失败率低,198例次中仅1例(0.5%)失败。
  • 定位结节平均大小10 mm±4,平均距胸膜10 mm±9。

核心结论

  • CT引导下肺结节基准标记放置安全、有效,外科定位失败率低。

研究设计与样本

  • 单中心回顾性分析,纳入2014至2020年连续接受CT引导下基准标记放置的患者,共198例次操作、190例患者(平均年龄64岁±12,121例女性),定位205个结节(平均大小10 mm±4,平均距胸膜10 mm±9)。

诊断标准与关键数值

  • 技术成功率98.5%(195/198)。
  • 无主要并发症。
  • 外科定位失败率0.5%(1例患者)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the technical success and complication rates of CT-guided fiducial marker placement for the localization of pulmonary nodules and to assess the surgical localization failure rate.

MATERIALS AND METHODS: This was a single-center, retrospective analysis of consecutive patients who underwent CT-guided fiducial marker placement procedures between 2014 and 2020. End points included the technical success of the fiducial marker placement, procedural complications, and the surgical localization failure rate. A two-sample t test and a Fisher exact test were used to compare continuous and categorical variables, respectively. Multivariate logistic regression was used to identify independent risk factors for complications.

RESULTS: A total of 198 preoperative CT-guided fiducial marker placement procedures were performed in 190 patients (mean age, 64 years ± 12 [standard deviation]; 121 women) to localize 205 nodules (mean size, 10 mm ± 4; mean distance to the pleura, 10 mm ± 9). The technical success rate was 98.5% (195 of 198). There were no major complications. A total of 202 nodules were resected during 193 procedures performed 5 days ± 13 after the fiducial marker placement (range, 0-123 days). Surgical localization failure occurred in one patient (0.5%). Of the resected nodules, 146 were lung cancers, 26 nodules were metastases, two were carcinoid tumors, and 28 were benign.

CONCLUSION: The CT-guided fiducial marker placement of pulmonary nodules was safe, effective, and resulted in a low surgical localization failure rate.Keywords: CT, Percutaneous, Thorax, Lung.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. McDermott, Frenk, Fintelmann, et al. Preoperative CT-guided Fiducial Marker Placement for Surgical Localization of Pulmonary Nodules. Radiol Cardiothorac Imaging. 2022. PMID: 35782764. doi:10.1148/ryct.210194

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。