深度学习合成CT与常规CT对颈椎骨结构显示的比较:单中心非劣效性图像质量研究
本研究纳入25例连续颈椎神经根病患者,配对采集MRI与CT数据,用T1加权多梯度回波序列重建深度学习合成CT(sCT),并与常规CT比较图像质量。定性评估显示sCT在整体骨图像质量、伪影、C3-C4与C6-C7椎间关节及神经孔显示、C6-C7皮质 delineation 方面非劣效于CT,但C3-C4皮质 delineation 与两节段骨小梁显示的非劣效性较弱至不存在。
要点
- 深度学习sCT在颈椎整体骨结构显示上非劣效于常规CT。
- sCT对椎间关节、神经孔及C6-C7皮质显示与CT相当。
- 骨小梁与C3-C4皮质显示的非劣效性较弱至不存在。
核心结论
- 基于深度学习的sCT在颈椎骨结构总体显示、伪影及多数细节结构评估上非劣效于常规CT。
研究设计与样本
- 单中心非劣效性研究,纳入25例连续颈椎神经根病患者(≥50岁),配对采集MRI与CT数据,sCT由T1加权多梯度回波序列重建,参考标准为常规CT,由三名评估者采用四点量表评分。
诊断标准与关键数值
- 非劣效界值为四点量表上0.5分;可接受图像质量定义为≥80%的扫描评分3-4分。
局限性
- 骨小梁与C3-C4皮质显示的非劣效性较弱至不存在。
- sCT骨小梁与CT C6-C7节段的可接受图像质量未达标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate whether the image quality of a specific deep learning-based synthetic CT (sCT) of the cervical spine is noninferior to conventional CT.
METHOD: Paired MRI and CT data were collected from 25 consecutive participants (≥ 50 years) with cervical radiculopathy. The MRI exam included a T1-weighted multiple gradient echo sequence for sCT reconstruction. For qualitative image assessment, four structures at two vertebral levels were evaluated on sCT and compared with CT by three assessors using a four-point scale (range 1-4). The noninferiority margin was set at 0.5 point on this scale. Additionally, acceptable image quality was defined as a score of 3-4 in ≥ 80% of the scans. Quantitative assessment included geometrical analysis and voxelwise comparisons.
RESULTS: Qualitative image assessment showed that sCT was noninferior to CT for overall bone image quality, artifacts, imaging of intervertebral joints and neural foramina at levels C3-C4 and C6-C7, and cortical delineation at C6-C7. Noninferiority was weak to absent for cortical delineation at level C3-C4 and trabecular bone at both levels. Acceptable image quality was achieved for all structures in sCT and CT, except for trabecular bone in sCT and level C6-C7 in CT. Geometrical analysis of the sCT showed good to excellent agreement with CT. Voxelwise comparisons showed a mean absolute error of 80.05 (±6.12) HU, dice similarity coefficient (cortical bone) of 0.84 (±0.04) and structural similarity index of 0.86 (±0.02).
CONCLUSIONS: This deep learning-based sCT was noninferior to conventional CT for the general visualization of bony structures of the cervical spine, artifacts, and most detailed structure assessments.
引用
- van der Kolk, Slotman, Nijholt, et al. Bone visualization of the cervical spine with deep learning-based synthetic CT compared to conventional CT: A single-center noninferiority study on image quality. Eur J Radiol. 2022. PMID: 35780607. doi:10.1016/j.ejrad.2022.110414
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。