文献速递妇产影像泌尿生殖MR

基于MRI影像组学列线图的开发与验证:用于评估早期子宫内膜样腺癌深肌层浸润

Development and Validation of an MRI-based Radiomics Nomogram for Assessing Deep Myometrial Invasion in Early Stage Endometrial Adenocarcinoma.
PubMed 文献 · Acad Radiol · 2022-06-29

本研究纳入266例I期子宫内膜样腺癌患者,分为训练组185例和测试组81例,基于多参数MRI影像组学特征和临床因素构建列线图评估深肌层浸润。临床参数、影像组学特征和列线图的AUC分别为0.744、0.869和0.883;两名放射科医生使用列线图后准确率分别从79.0%和80.2%提高至90.1%和92.5%。列线图可帮助放射科医生评估深肌层浸润并提高预测准确率。

要点

  • 列线图评估深肌层浸润的AUC为0.883,高于临床参数0.744和影像组学特征0.869。
  • 两名放射科医生使用列线图后准确率分别从79.0%和80.2%提高至90.1%和92.5%。
  • 交叉验证显示影像组学分析结果可能不受场强变化影响。

核心结论

  • 基于影像组学特征和临床因素的列线图可帮助放射科医生评估早期子宫内膜样腺癌的深肌层浸润并提高预测准确率。

研究设计与样本

  • 共纳入266例I期子宫内膜样腺癌患者,分为训练组185例和测试组81例;从多参数MR图像提取和筛选影像组学特征,采用逻辑回归识别临床预测因子,整合重要临床因素和影像组学特征构建列线图,用ROC曲线评估,并由两名放射科医生在有或无列线图辅助下评估MR图像检测深肌层浸润。

诊断标准与关键数值

  • 年龄和CA125为独立临床预测因子;临床参数、影像组学特征和列线图评估深肌层浸润的AUC分别为0.744、0.869和0.883;两名放射科医生的NRI分别为0.262和0.318,IDI分别为0.322和0.405。

临床应用与阅片要点

  • 两名放射科医生在有列线图辅助下评估MR图像检测深肌层浸润的准确率分别为90.1%和92.5%,高于无辅助时的79.0%和80.2%;决策曲线分析显示列线图较影像组学特征或无辅助放射科医生有更高的净获益。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To establish a radiomics nomogram for detecting deep myometrial invasion (DMI) in early stage endometrioid adenocarcinoma (EAC).

MATERIALS AND METHODS: A total of 266 patients with stage I EAC were divided into training (n = 185) and test groups (n = 81). Logistic regression were used to identify clinical predictors. Radiomics features were extracted and selected from multiparameter MR images. The important clinical factors and radiomics features were integrated into a nomogram. A receiver operating characteristic curve was used to evaluate the nomogram. Two radiologists evaluated MR images with or without the help of the nomogram to detect DMI. The clinical benefit of using the nomogram was evaluated by decision curve analysis (DCA) and by calculating net reclassification index (NRI) and integrated discrimination index (IDI).

RESULTS: Age and CA125 were independent clinical predictors. The area under the curves of the clinical parameters, radiomics signature and nomogram in evaluating DMI were 0.744, 0.869 and 0.883, respectively. The accuracies of the two radiologists increased from 79.0% and 80.2% to 90.1% and 92.5% when they used the nomogram. The NRI of the two radiologists were 0.262 and 0.318, and the IDI were 0.322 and 0.405. According to DCA, the nomogram showed a higher net benefit than the radiomics signature or unaided radiologists. Cross-validation showed the outcome of radiomics analysis may not be influenced by changes in field strength.

CONCLUSION: The radiomics nomogram based on radiomics features and clinical factors can help radiologists evaluate DMI and improve their accuracy in predicting DMI in early stage EAC.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Bi, Deng, et al. Development and Validation of an MRI-based Radiomics Nomogram for Assessing Deep Myometrial Invasion in Early Stage Endometrial Adenocarcinoma. Acad Radiol. 2022. PMID: 35778306. doi:10.1016/j.acra.2022.05.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。