涡量评估的冠状动脉血流扰动作为功能性显著狭窄的成因
本研究回顾性纳入113例冠状动脉CT血管成像显示中度狭窄并接受有创血流储备分数(FFR)检查的患者(共144支血管),用无网格计算流体力学计算狭窄处涡量,发现涡量与有创FFR呈负相关,且在多变量分析中独立于最小管腔面积和直径狭窄率预测功能性显著狭窄,涡量联合几何狭窄指标可提高诊断效能。
要点
- 功能性显著狭窄(FFR≤0.80)的涡量显著高于非显著狭窄(569±78 vs 328±34 s-1)。
- 涡量每增加100 s-1,检出功能性显著狭窄的OR为1.36(95%CI 1.21-1.57),独立于几何狭窄。
- 涡量联合直径狭窄率和最小管腔面积使AUC从0.76升至0.87(p=0.001)。
核心结论
- 涡量与有创FFR呈独立于几何狭窄的显著负相关,对检出功能性显著狭窄具有附加价值。
研究设计与样本
- 回顾性研究,纳入2015年12月至2020年3月间113例冠状动脉CT血管成像显示中度狭窄并接受有创FFR检查的患者,共评估144支血管,采用无网格计算流体力学方法计算狭窄处涡量,以有创FFR≤0.80为功能性显著狭窄参考标准。
诊断标准与关键数值
- 有创FFR≤0.80定义为功能性显著狭窄;显著狭窄涡量569±78 s-1 vs 非显著狭窄328±34 s-1(p<0.001);涡量与有创FFR呈负相关(R2=0.31,p<0.001);多变量分析中涡量(每100 s-1)OR 1.36(95%CI 1.21-1.57,p<0.001);涡量联合直径狭窄率和最小管腔面积AUC 0.87 vs 单独几何指标AUC 0.76(p=0.001)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Vorticity calculated using computational fluid dynamics (CFD) could assess the flow disturbance generated by coronary stenosis. The purpose of this study was to investigate whether vorticity would be an underlying cause of functionally significant stenosis assessed by invasive fractional flow reserve (FFR).
METHODS: This retrospective study included 113 patients who underwent coronary CT angiography showing intermediate stenosis and subsequent invasive FFR between December 2015 and March 2020. Vorticity at the stenosis site was calculated using a mesh-free CFD method. We also evaluated the minimum lumen area (MLA) and diameter stenosis (DS) of the lesion. Invasive FFR of ≤ 0.80 was considered functionally significant. Data were compared using Student's t-test and logistic regression analysis was performed.
RESULTS: Of the evaluated 144 vessels, 53 vessels (37%) showed FFR ≤ 0.80. Vorticity of significant stenosis was significantly higher than non-significant stenosis (569 ± 78 vs. 328 ± 34 s-1, p < 0.001). A significant negative relationship was present between vorticity and invasive FFR (R2 = 0.31, p < 0.001). Multivariate logistic regression analysis including MLA and DS showed that vorticity (per 100 s-1, odds ratio: 1.36, 95% confidence interval: 1.21-1.57, p < 0.001) was a statistically significant factor to detect functional significance. The area under the receiver operating characteristic curve statistically significantly increased when vorticity was combined with DS and MLA (0.76 vs. 0.87, p = 0.001).
CONCLUSIONS: Vorticity had a statistically significant negative relationship with invasive FFR independent of geometric stenosis.
KEY POINTS: • Flow disturbance caused by coronary stenosis could be evaluated by calculating vorticity which is defined as the norm of the rotation of the velocity vector. • Vorticity was statistically significantly higher in stenosis with functional significance than stenosis without. • Vorticity has an additive value to detect functionally significant stenosis over geometrical stenosis.
引用
- Tomizawa, Nozaki, Fujimoto, et al. Coronary flow disturbance assessed by vorticity as a cause of functionally significant stenosis. Eur Radiol. 2022. PMID: 35778509. doi:10.1007/s00330-022-08974-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。