Silk Vista Baby血流导向支架治疗破裂颅内动脉瘤:一项回顾性观察性研究
该多中心回顾性观察性研究纳入12家意大利中心连续25例破裂颅内动脉瘤患者,采用新一代低剖面Silk Vista Baby血流导向支架治疗,3个月随访79.1%患者预后良好(mRS 0-2),85.7%患者动脉瘤完全闭塞,无再出血;不良WFNS分级和后循环位置与不良预后显著相关。作者认为对于Willis环远端的破裂动脉瘤,低剖面血流导向支架治疗可行,可能成为经过仔细筛选病例的替代选择。
要点
- 3个月随访79.1%患者预后良好(mRS 0-2),12.5%死亡。
- 3个月随访85.7%患者动脉瘤完全闭塞,随访期间无再出血。
- 支架内血栓发生2例(8.3%),经糖蛋白IIb/IIIA和支架内血管成形术处理,无临床后果。
核心结论
- 数据提示低剖面血流导向支架治疗位于Willis环远端的破裂颅内动脉瘤可行,新一代低剖面血流导向支架可能成为经过仔细筛选病例的替代选择。
研究设计与样本
- 回顾性观察性研究,纳入12家意大利中心连续25例接受Silk Vista Baby血流导向支架治疗的破裂颅内动脉瘤患者。
诊断标准与关键数值
- 主要终点为3个月时良好临床预后率,定义为改良Rankin评分(mRS)0-2分;3个月随访19例(79.1%)达到良好临床预后。
- 次要终点包括并发症率、动脉瘤再破裂和末次影像随访时动脉瘤完全闭塞;3个月随访18例(85.7%)显示动脉瘤完全闭塞。
- 随访期间3例(12.5%)死亡,无再出血发生。
- 支架内血栓发生2例(8.3%),经糖蛋白IIb/IIIA和支架内血管成形术处理,无临床后果。
- 不良WFNS分级和后循环位置均与不良临床预后显著相关(p=0.005和p=0.02)。
临床应用与阅片要点
- 作者认为低剖面血流导向支架治疗Willis环远端破裂颅内动脉瘤可行。
- 作者认为新一代低剖面血流导向支架可能成为经过仔细筛选病例的替代选择。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Flow diversion changed the approach to complex intracranial aneurysms, leading to a widespread use and a rapid technological evolution. Indeed, indications continued to expand, including ruptured intracranial aneurysms in selected cases. Recently, new devices have been designed specifically to target smaller vessels. Therefore, we conducted a multicenter study to evaluate clinical outcome, complications, and occlusion rate of patients with ruptured aneurysms treated with new generation low profile Silk Vista Baby (SVB) flow diverter stent (FD).
METHODS: We performed a retrospective observational study on consecutive patients who underwent treatment with SVB for ruptured aneurysms at 12 Italian centers. Primary end point was favorable clinical outcome rate, defined as modified ranking score (mRS) of 0-2 at the 3 months. Secondary outcomes were complication rate, aneurysm re-rupture, and complete aneurysm occlusion at last radiological follow-up.
RESULTS: Twenty-five patients were included; at 3 months' follow-up, 19 patients (79.1%) had favorable clinical outcome (mRS 0-2). Three patients (12.5%) died during follow-up. In-stent thrombosis occurred in two cases (8.3%), managed with glycoprotein IIb/IIIA and intra-stent angioplasty, without clinical consequences. In 18 (85.7%) patients, complete occlusion at 3 months was demonstrated. No rebleeding occurred during follow-up. Presentation with unfavorable World Federation of Neurosurgical Societies grading system (WFNS) and posterior circulation location were both significantly correlated with unfavorable clinical outcome (p = 0.005 and p = 0.02).
CONCLUSIONS: Our data suggests that low profile FD treatment of ruptured intracranial aneurysms located distally of the circle of Willis is feasible. New generation low profile FD may represent an alternative option in carefully selected cases.
引用
- Russo, Boghi, Giorgianni, et al. Silk Vista Baby flow diverter stent for ruptured intracranial aneurysms: a retrospective observational study. Neuroradiology. 2022. PMID: 35773522. doi:10.1007/s00234-022-03003-x