通过双平面血管造影系统专项培训降低神经介入中的辐射暴露
研究回顾性收集57例神经介入手术的剂量数据,比较经培训能独立操作双平面血管造影系统的介入医师与由放射技师辅助操作的高年资介入医师的辐射剂量。独立操作组平均剂量为4,655 μGy·m2,显著低于技师辅助组的7,000 μGy·m2以上(p<0.05),平均剂量降低幅度可达38%。作者认为操作技能的提升有助于降低辐射剂量,应纳入介入放射学培训课程。
要点
- 介入医师独立操作双平面血管造影系统时平均剂量为4,655 μGy·m2,显著低于技师辅助组的7,000 μGy·m2以上。
- 独立操作可使平均辐射剂量降低幅度达38%。
- 作者认为操作双平面血管造影系统的知识与技能应纳入介入放射学培训课程。
核心结论
- 本研究提示,介入医师提高对双平面血管造影系统的操作知识和技能有助于降低神经介入手术中的辐射剂量。
研究设计与样本
- 回顾性研究,回顾性收集57例神经介入手术的剂量面积乘积数据,比较经培训能独立操作双平面血管造影系统的介入医师与由放射技师辅助操作双平面血管造影系统的高年资介入医师的辐射剂量。
诊断标准与关键数值
- 独立操作双平面血管造影系统的介入医师平均剂量为4,655 μGy·m2,显著低于技师辅助操作双平面血管造影系统的7,000 μGy·m2以上(p<0.05)。
- 独立操作使平均辐射剂量降低幅度可达38%。
临床应用与阅片要点
- 作者认为,提高操作双平面血管造影系统的知识和技能可使介入医师有机会尽量减少辐射剂量,这应成为合格神经介入医师所需技能的一部分,并在介入放射学课程中正式涉及。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate whether the radiation dose in neurointerventional procedures is reduced if the interventionalist has a better working knowledge and skill to operate the biplane angiographic system (BAS).
MATERIALS AND METHODS: It is common practice in most centres in the UK for radiographers to drive many of the functions of the BAS under the instruction of the interventionalist who performs the procedure. The dose profile of a neurointerventionalist who was trained to perform procedures while operating the BAS independently was evaluated against that of a highly experienced neurointerventionalist when operating with a radiographer-assisted BAS.
RESULTS: The dose-area product for 57 procedures was collected retrospectively. Working independently resulted in a statistically significant lower mean dose of 4,655 μGy·m2 compared to mean doses above 7,000 μGy·m2 with a radiographer-assisted BAS (p<0.05). Effectively this allowed for the mean dose to be reduced by as much as 38%.
CONCLUSION: This study suggests that improved knowledge and skill in operating the BAS gives the neurointerventionalist the opportunity to minimise radiation dose. Therefore, this should be part of the skillset acquired by a qualified neurointerventionalist and be formally addressed in the interventional radiology curriculum.18.