SARS-CoV-2住院患者胸部CT表现:Delta变异株与Omicron变异株的比较
本回顾性研究纳入Delta变异株占优势期间和Omicron变异株占优势期间住院的SARS-CoV-2患者各88例,比较两组基线胸部CT的RSNA分类、肺炎范围及血管定量指标。Omicron组典型外周双侧磨玻璃影出现率较低、支气管血管周围分布倾向较高,视觉肺炎范围较低,而肺炎体积无显著差异,且BV5%较高。调整分析后Omicron与不典型表现、支气管血管周围分布及较高BV5%相关,视觉肺炎范围和肺炎体积与Delta组相似。
要点
- 住院SARS-CoV-2患者中,Omicron组典型外周双侧磨玻璃影出现率低于Delta组(32% vs 57%,P=.001)。
- Omicron组支气管血管周围分布倾向更常见(38% vs 7%,P<.001)。
- Omicron组视觉肺炎范围较低(5.4±6.0 vs 7.7±6.6,P=.02),但肺炎体积两组无显著差异(P=.14)。
核心结论
- 在疾病严重程度相似的住院患者中,胸部CT上Omicron变异株表现为不典型的支气管血管周围肺炎,且肺部血管受累程度低于Delta变异株。
研究设计与样本
- 回顾性研究,在Delta和Omicron变异株分别占优势期间,从一家二级转诊医院连续收集住院SARS-CoV-2患者的基线胸部CT图像。
关键影像表现/征象
- Omicron组典型外周双侧磨玻璃影出现率低于Delta组(32% [28/88] vs 57% [50/88],P=.001)。
- Omicron组支气管血管周围分布倾向高于Delta组(38% [25/66] vs 7% [5/71],P<.001)。
- Omicron组视觉肺炎范围低于Delta组(5.4±6.0 vs 7.7±6.6,P=.02)。
- Omicron组与Delta组肺炎体积无显著差异(5%±1 vs 7%±11,P=.14)。
- Omicron组BV5%高于Delta组(48%±11 vs 44%±8,P=.004)。
诊断标准与关键数值
- 两名放射科医师按RSNA COVID-19分类系统对CT图像进行分类,并视觉分级肺炎范围。
- 调整分析中,Omicron与不典型表现相关(OR=0.34,P=.006),与支气管血管周围分布相关(OR=9.2,P<.001),与较高BV5%相关(β=3.8,P=.01)。
- 调整分析中,Omicron与Delta相比视觉肺炎范围相似(P=.17),肺炎体积相似(P=.67)。
临床应用与阅片要点
- 住院SARS-CoV-2患者阅片时,Omicron变异株可表现为不典型的支气管血管周围分布肺炎,而非典型外周双侧磨玻璃影。
- Omicron组视觉肺炎范围较低但肺炎体积与Delta组无显著差异,提示视觉评估与定量体积可能不一致。
- Omicron组BV5%较高,提示肺部小血管受累比例可能低于Delta组。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background CT manifestations of SARS-CoV-2 may differ among variants. Purpose To compare the chest CT findings of SARS-CoV-2 between the Delta and Omicron variants. Materials and Methods This retrospective study collected consecutive baseline chest CT images of hospitalized patients with SARS-CoV-2 from a secondary referral hospital when the Delta and Omicron variants were predominant. Two radiologists categorized CT images according to the RSNA classification system for COVID-19 and visually graded pneumonia extent. Pneumonia, pleural effusion, and intrapulmonary vessels were segmented and quantified on CT images using a priori-developed neural networks, followed by reader confirmation. Multivariable logistic and linear regression analyses were performed to examine the associations between the variants and CT category, distribution, severity, and peripheral vascularity. Results In total, 88 patients with the Delta variant (mean age, 67 years ± 15 [SD]; 46 men) and 88 patients with the Omicron variant (mean age, 62 years ± 19; 51 men) were included. Omicron was associated with less frequent, typical peripheral bilateral ground-glass opacity (32% [28 of 88] vs 57% [50 of 88], P = .001), more frequent peribronchovascular predilection (38% [25 of 66] vs 7% [five of 71], P < .001), lower visual pneumonia extent (5.4 ± 6.0 vs 7.7 ± 6.6, P = .02), similar pneumonia volume (5% ± 1 vs 7% ± 11, P = .14), and a higher proportion of vessels with a cross-sectional area smaller than 5 mm2 relative to the total pulmonary blood volume (BV5%; 48% ± 11 vs 44% ± 8; P = .004). In adjusted analyses, Omicron was associated with a nontypical appearance (odds ratio, 0.34; P = .006), peribronchovascular predilection (odds ratio, 9.2; P < .001), and higher BV5% (β = 3.8; P = .01) but similar visual pneumonia extent (P = .17) and pneumonia volume (P = .67) relative to the Delta variant. Conclusion At chest CT, the Omicron SARS-COV-2 variant showed nontypical peribronchovascular pneumonia and less pulmonary vascular involvement than did the Delta variant in hospitalized patients with similar disease severity. © RSNA, 2022 Online supplemental material is available for this article.
引用
- Yoon, Lee, Kim, et al. Chest CT Findings in Hospitalized Patients with SARS-CoV-2: Delta versus Omicron Variants. Radiology. 2022. PMID: 35762887. doi:10.1148/radiol.220676
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。